Literature DB >> 6883051

Errors inherent in the performance of a routine semen analysis.

A M Jequier, E B Ukombe.   

Abstract

A group of 26 medical laboratory technicians and pathologists performed a semen analysis on an aliquot of the same sample of semen. The mean sperm concentration obtained was 46.7 X 10(6)/ml +/- 40.1 (2 s.d.) with a range of values lying between 10 and 98 X 10(6)/ml and giving a coefficient of variation of 44.3%. Similar wide ranges were seen in the visual estimation of percentage motility and abnormal morphology. Results obtained from three technicians, all highly experienced in performing semen analyses, produced a mean sperm concentration of 66 X 10(6)/ml with a coefficient of variation of 37.8%. When the sperm concentration in semen was low, replicate analyses of four separate semen specimens produced coefficients of variation that were unacceptably high.

Mesh:

Year:  1983        PMID: 6883051     DOI: 10.1111/j.1464-410x.1983.tb03339.x

Source DB:  PubMed          Journal:  Br J Urol        ISSN: 0007-1331


  6 in total

1.  Status of semen analysis-comment on "A survey on the status of semen analysis in 118 laboratories in China" by Jin-Chun Lu et al. in Asian Journal of Andrology.

Authors:  Hugh William Gordon Baker
Journal:  Asian J Androl       Date:  2010-01       Impact factor: 3.285

2.  External quality control program for semen analysis: Spanish experience.

Authors:  C Alvarez; J A Castilla; J P Ramírez; F Vergara; A Yoldi; A Fernández; J J Gaforio
Journal:  J Assist Reprod Genet       Date:  2005-12       Impact factor: 3.412

3.  Interpretation of semen analysis among infertile couples.

Authors:  D R Small; J A Collins; E H Wilson; W Wrixon
Journal:  CMAJ       Date:  1987-04-15       Impact factor: 8.262

4.  Accuracy of sperm velocity assessment using the Sperm Quality Analyzer V.

Authors:  Yuki Hirano; Hiroaki Shibahara; Kazuhiko Shimada; Seiji Yamanaka; Tatsuya Suzuki; Satoru Takamizawa; Mitsuhiro Motoyama; Mitsuaki Suzuki
Journal:  Reprod Med Biol       Date:  2004-01-29

5.  Evaluating the accuracy of different sperm counting chambers by performing strict counts of photographed beads.

Authors:  E Shiran; J Stoller; Z Blumenfeld; P D Feigin; A Makler
Journal:  J Assist Reprod Genet       Date:  1995-08       Impact factor: 3.412

6.  Morphometry of spermatozoa using semiautomatic image analysis.

Authors:  J R Jagoe; N P Washbrook; E A Hudson
Journal:  J Clin Pathol       Date:  1986-12       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.