Uncemented acetabular replacement.

P A Ring.   

Abstract

An uncemented Polyethylene acetabular component has been developed using a cup of conical outer configuration locked in position with the Freeman osseous peg. This cup is available in four sizes and is normally used with an uncemented femoral component. During the last 3 years 875 implants of this sort have been inserted and the results in these patients who are between 1 and 3 years post-operatively have been compared with the results in 236 replacements of a similar configuration but secured with bone cement in the usual way. The two groups have been demonstrated to be comparable in pre-operative diagnosis, age and sex. The results using the uncemented articulation are broadly the same as those using the cemented joint during the period of study but the acetabular component in 30% of the cemented joints showed a zone of demarcation between cement and bone whereas only one of the uncemented acetabular components showed similar radiological changes. The examination of the radiographs of the uncemented group suggests that the pelvic bone responds favourably to the stresses which are imposed upon it provided that the centre of the joint movement is relocated in the anatomical position, under these circumstances bone will usually build up to support the cup in a dysplastic acetabulum and in the floor of a central protrusion.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6882161     DOI: 10.1007/bf00379935

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0344-8444


  3 in total

1.  Total hip replacement--past, present and future.

Authors:  G K McKee
Journal:  Biomaterials       Date:  1982-07       Impact factor: 12.479

2.  Ten-year follow-up study of total hip replacement.

Authors:  R N Stauffer
Journal:  J Bone Joint Surg Am       Date:  1982-09       Impact factor: 5.284

3.  A ten-year follow-up of one hundred consecutive Müller curved-stem total hip-replacement arthroplasties.

Authors:  C J Sutherland; A H Wilde; L S Borden; K E Marks
Journal:  J Bone Joint Surg Am       Date:  1982-09       Impact factor: 5.284

  3 in total
  4 in total

Review 1.  Is there evidence for a superior method of socket fixation in hip arthroplasty? A systematic review.

Authors:  Dean Pakvis; Gijs van Hellemondt; Enrico de Visser; Wilco Jacobs; Maarten Spruit
Journal:  Int Orthop       Date:  2011-03-15       Impact factor: 3.075

2.  Ring uncemented plastic on metal hip replacements--results from an independent unit.

Authors:  D W Mok; K M Bryant
Journal:  J R Soc Med       Date:  1989-03       Impact factor: 5.344

3.  Cementless acetabular replacement using a pegged polyethylene prosthesis.

Authors:  K C Bertin; M A Freeman; E Morscher; A Oeri; P A Ring
Journal:  Arch Orthop Trauma Surg       Date:  1985

4.  Blood loss associated with uncemented total hip replacement: hypotension does not affect blood loss.

Authors:  F W Wittmann
Journal:  J R Soc Med       Date:  1987-04       Impact factor: 18.000