Literature DB >> 6871897

Evaluation of functional capacity during exercise radionuclide angiography.

C Foster, M L Pollock, J L Rod, D S Dymond, G Wible, D H Schmidt.   

Abstract

This study compared functional capacity during treadmill exercise testing and during bicycle exercise radionuclide angiography. 262 patients performed maximal upright bicycle exercise and also performed maximal graded exercise testing using either the Bruce (n = 158) or Naughton (n = 104) treadmill protocols. The functional capacity was well correlated between bicycle and treadmill for Bruce (r = 0.89), Naughton (r = 0.93), or combined treadmill (r = 0.90) protocols. However, the functional capacity was significantly lower during bicycle than during treadmill testing for Bruce (8.3 vs. 10.5 METs), Naughton (7.8 vs. 8.7 METs), or combined treadmill (8.1 vs. 9.8 METs) protocols. Treadmill functional capacity could be predicted from bicycle functional capacity using the following equations: Bruce METs = 1.00 X (bike METs) + 2.23, Naughton METs = 0.94 X (bike METs) + 1.40, and combined treadmill METs = 0.98 X (bike METs) + 1.85.

Entities:  

Mesh:

Year:  1983        PMID: 6871897     DOI: 10.1159/000173574

Source DB:  PubMed          Journal:  Cardiology        ISSN: 0008-6312            Impact factor:   1.869


  6 in total

Review 1.  Stress testing. Directions for the future.

Authors:  C Foster
Journal:  Sports Med       Date:  1988-07       Impact factor: 11.136

2.  Assessment of left ventricular function during upright treadmill exercise with tantalum 178 and multiwire gamma camera.

Authors:  Jaekyeong Heo; Thein Htay; Deval Mehta; Liang Sun; Jeffrey Lacy; Ami E Iskandrian
Journal:  J Nucl Cardiol       Date:  2005 Sep-Oct       Impact factor: 5.952

3.  First-pass radionuclide angiography during bicycle and treadmill exercise.

Authors:  C Foster; T Gaeckle; R Braastad; D H Schmidt; S C Port
Journal:  J Nucl Cardiol       Date:  1995 Nov-Dec       Impact factor: 5.952

4.  Assessment of exercise capacity in African patients with chronic heart failure using six minutes walk test.

Authors:  Rufus A Adedoyin; Samuel A Adeyanju; Michael O Balogun; Anthony O Akintomide; Rasaaq A Adebayo; Patience O Akinwusi; Taofeek O Awotidebe
Journal:  Int J Gen Med       Date:  2010-04-08

5.  Low agreement of ventilatory threshold between training modes in cardiac patients.

Authors:  Dominique Hansen; Paul Dendale; Jan Berger; Romain Meeusen
Journal:  Eur J Appl Physiol       Date:  2007-08-01       Impact factor: 3.078

6.  Effect of Tinospora cordifolia on physical and cardiovascular performance induced by physical stress in healthy human volunteers.

Authors:  Bharat A Salve; Raakhi K Tripathi; Anup U Petare; Ashwinikumar A Raut; Nirmala N Rege
Journal:  Ayu       Date:  2015 Jul-Sep
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.