Literature DB >> 6866442

Ophthalmic prisms. Measurement errors and how to minimize them.

J T Thompson, D L Guyton.   

Abstract

Variable results of strabismus surgery may be due in part to errors in prism measurement. The amount of deviation neutralized by an ophthalmic prism is variable depending on how the prism is held. For example, a 40 delta glass prism with the posterior face held in the frontal plane gives only 32 delta of effect. Glass prisms are calibrated for use in the Prentice position. Plastic prisms are calibrated for use in the frontal plane position. Surprisingly large errors in prism measurement are produced when adding a small prism to a large prism. For example, adding a 5 delta glass prism to a 40 delta glass prism gives not 45 delta of effect, but 59 delta. This error can be minimized but not eliminated by holding one prism in front of each eye. The error can also be calculated so that the appropriate correction can be made.

Entities:  

Mesh:

Year:  1983        PMID: 6866442     DOI: 10.1016/s0161-6420(83)34572-3

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  17 in total

1.  Three horizontal muscle surgery for large-angle infantile esotropia: validation of a table of amounts of surgery.

Authors:  J E Camuglia; M J Walsh; G A Gole
Journal:  Eye (Lond)       Date:  2011-08-05       Impact factor: 3.775

2.  Intraocular pressure decreases after muscle union surgery for highly myopic strabismus.

Authors:  Shion Hayashi; Miho Sato; Hitomi Miura; Akira Sugano; Mai Yamazaki; Hidetoshi Yamashita
Journal:  Jpn J Ophthalmol       Date:  2014-12-18       Impact factor: 2.447

3.  Intermittent exotropia: relation between age and surgical outcome: a change-point analysis.

Authors:  A Awadein; R M Eltanamly; M Elshazly
Journal:  Eye (Lond)       Date:  2014-02-28       Impact factor: 3.775

4.  Analysis of the dosage controversy in recess-resect and Faden surgery with the Robinson computer model of eye movements.

Authors:  H J Simonsz; B van Dijk
Journal:  Doc Ophthalmol       Date:  1987-11       Impact factor: 2.379

5.  Remote optical systems for ophthalmic examination.

Authors:  D L Guyton
Journal:  Trans Am Ophthalmol Soc       Date:  1986

6.  The broad clinical spectrum of early infantile esotropia.

Authors:  R M Robb; D W Rodier
Journal:  Trans Am Ophthalmol Soc       Date:  1986

7.  Comitant strabismus: Perspectives, present and future.

Authors:  Darren T Oystreck; Christopher J Lyons
Journal:  Saudi J Ophthalmol       Date:  2012-05-23

8.  Interobserver reliability of the prism and alternate cover test in children with esotropia.

Authors: 
Journal:  Arch Ophthalmol       Date:  2009-01

9.  Variability of Ocular Deviation in Strabismus.

Authors:  John R Economides; Daniel L Adams; Jonathan C Horton
Journal:  JAMA Ophthalmol       Date:  2016-01       Impact factor: 7.389

10.  Characteristics and surgical outcomes of consecutive exotropia of different etiologies.

Authors:  Mayu Sawada; Akiko Hikoya; Takashi Negishi; Yoshihiro Hotta; Miho Sato
Journal:  Jpn J Ophthalmol       Date:  2015-08-06       Impact factor: 2.447

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.