Literature DB >> 6861293

Toxic effects of silver-silver chloride electrodes on vascular smooth muscle.

W F Jackson, B R Duling.   

Abstract

We found that silver, either as silver metal or silver chloride, exerted toxic effects on the smooth muscle of isolated cannulated hamster cheek pouch arterioles. Silver initially stimulated the smooth muscle, producing a marked vasoconstriction. The vessels then dilated back to control diameters. Once the arterioles began to dilate, they became refractory to norepinephrine or potassium stimulation. We caution the use of silver in the presence of smooth muscle, especially when tissue mass is small or free protein concentration is low.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6861293     DOI: 10.1161/01.res.53.1.105

Source DB:  PubMed          Journal:  Circ Res        ISSN: 0009-7330            Impact factor:   17.367


  9 in total

Review 1.  Biosensors: a viable monitoring technology?

Authors:  S P Higson; P M Vadgama
Journal:  Med Biol Eng Comput       Date:  1994-11       Impact factor: 2.602

Review 2.  Biocompatible reference electrodes to enhance chronic electrochemical signal fidelity in vivo.

Authors:  Blake T Seaton; Michael L Heien
Journal:  Anal Bioanal Chem       Date:  2021-10-01       Impact factor: 4.142

3.  Large-scale intramuscular electrode system for chronic electromyography and functional electrical stimulation.

Authors:  Nicole L Holly; Brady A Hasse; Katalin M Gothard; Andrew J Fuglevand
Journal:  J Neurophysiol       Date:  2022-09-21       Impact factor: 2.974

4.  Development of a platinized platinum/iridium electrode for use in vitro.

Authors:  K R Cote; R C Gill
Journal:  Ann Biomed Eng       Date:  1987       Impact factor: 3.934

5.  K+-induced dilation of hamster cremasteric arterioles involves both the Na+/K+-ATPase and inward-rectifier K+ channels.

Authors:  Wendy R Burns; Kenneth D Cohen; William F Jackson
Journal:  Microcirculation       Date:  2004 Apr-May       Impact factor: 2.628

6.  Sol-gel deposition of iridium oxide for biomedical micro-devices.

Authors:  Cuong M Nguyen; Smitha Rao; Xuesong Yang; Souvik Dubey; Jeffrey Mays; Hung Cao; Jung-Chih Chiao
Journal:  Sensors (Basel)       Date:  2015-02-12       Impact factor: 3.576

7.  Establishment and evaluation of a reversible two-kidney, one-clip renovascular hypertensive rat model.

Authors:  Li-Qiang Li; Jian Zhang; Rong Wang; Jian-Xin Li; Yong-Quan Gu
Journal:  Exp Ther Med       Date:  2017-04-26       Impact factor: 2.447

8.  Transistor in a tube: A route to three-dimensional bioelectronics.

Authors:  C Pitsalidis; M P Ferro; D Iandolo; L Tzounis; S Inal; R M Owens
Journal:  Sci Adv       Date:  2018-10-26       Impact factor: 14.136

9.  Accurate and stable chronic in vivo voltammetry enabled by a replaceable subcutaneous reference electrode.

Authors:  Elaine Marie Robbins; Elisa Castagnola; Xinyan Tracy Cui
Journal:  iScience       Date:  2022-08-02
  9 in total