Literature DB >> 36129191

Large-scale intramuscular electrode system for chronic electromyography and functional electrical stimulation.

Nicole L Holly1, Brady A Hasse2, Katalin M Gothard1,3,4, Andrew J Fuglevand1,3.   

Abstract

To understand how the central nervous system (CNS) enacts movements, it seems important to monitor the activities of the many muscles involved. Likewise, to restore complex movements to paralyzed limbs with electrical stimulation requires access to most limb muscles. Intramuscular electrodes are needed to obtain isolated recordings or stimulation of individual muscles. As such, we developed and tested the stability of large arrays of implanted intramuscular electrodes. We implanted 58 electrodes in 29 upper limb muscles in each of three macaques. Electrode connectors were protected within a skull-mounted chamber. During surgery, wires were tunneled subcutaneously to target muscles, where gold anchors were crimped onto the leads. The anchors were then deployed with an insertion device. In two monkeys, the chamber was fixed to the skull with a titanium baseplate rather than acrylic cement. In multiple sessions up to 15 wk after surgery, electromyographic (EMG) signals were recorded while monkeys made the same reaching movement. EMG signals were stable, with an average (SD) coefficient of variation across sessions of 0.24 ± 0.15. In addition, at 4, 8, and 16 wk after surgery, forces to incrementing stimulus pulses were measured for each electrode. The threshold current needed to evoke a response at 16 wk was not different from that at 4 wk. Likewise, peak force evoked by 16 mA of current at 16 wk was not different from 4 wk. The stability of this system implies it could be effectively used to monitor and stimulate large numbers of muscles needed to understand the control of natural and evoked movements.NEW AND NOTEWORTHY A new method was developed to enable long-lasting recording and stimulation of large numbers of muscles with intramuscular electrodes. Electromyographic signals and evoked force responses in 29 upper limb muscles remained stable over several months when tested in nonhuman primates. This system could be used effectively to monitor and stimulate numerous muscles needed to more fully understand the control of natural and evoked movements.

Entities:  

Keywords:  electrodes; electromyography; functional electrical stimulation; stability

Mesh:

Substances:

Year:  2022        PMID: 36129191      PMCID: PMC9550579          DOI: 10.1152/jn.00325.2022

Source DB:  PubMed          Journal:  J Neurophysiol        ISSN: 0022-3077            Impact factor:   2.974


  44 in total

1.  Characteristics of motor programs underlying arm movements in monkeys.

Authors:  A Polit; E Bizzi
Journal:  J Neurophysiol       Date:  1979-01       Impact factor: 2.714

2.  Clinical experience with reinforced, anchored intramuscular electrodes for functional neuromuscular stimulation.

Authors:  A Prochazka; L A Davis
Journal:  J Neurosci Methods       Date:  1992-05       Impact factor: 2.390

Review 3.  Functional electrical stimulation for neuromuscular applications.

Authors:  P Hunter Peckham; Jayme S Knutson
Journal:  Annu Rev Biomed Eng       Date:  2005       Impact factor: 9.590

4.  Methods for chronic recording of EMG activity from large numbers of hindlimb muscles in awake rhesus macaques.

Authors:  Heather M Hudson; Darcy M Griffin; Abderraouf Belhaj-Saïf; Sang-Pil Lee; Paul D Cheney
Journal:  J Neurosci Methods       Date:  2010-03-25       Impact factor: 2.390

5.  Muscle activity for initiation of planar, two-joint arm movements in different directions.

Authors:  Z Hasan; G M Karst
Journal:  Exp Brain Res       Date:  1989       Impact factor: 1.972

6.  Displacement, deformation and fracture of wire electrodes for electromyography.

Authors:  B Jonsson; U E Bagge
Journal:  Electromyography       Date:  1968 Nov-Dec

7.  An organizing principle for a class of voluntary movements.

Authors:  N Hogan
Journal:  J Neurosci       Date:  1984-11       Impact factor: 6.167

8.  Modulation of muscle force by recruitment during intramuscular stimulation.

Authors:  P E Crago; P H Peckham; G B Thrope
Journal:  IEEE Trans Biomed Eng       Date:  1980-12       Impact factor: 4.538

9.  Modified mesh for hernia repair that is adapted to the physiology of the abdominal wall.

Authors:  U Klinge; B Klosterhalfen; J Conze; W Limberg; B Obolenski; A P Ottinger; V Schumpelick
Journal:  Eur J Surg       Date:  1998-12

10.  Customizable cap implants for neurophysiological experimentation.

Authors:  Jackson D Blonde; Megan Roussy; Rogelio Luna; Borna Mahmoudian; Roberto A Gulli; Kevin C Barker; Jonathan C Lau; Julio C Martinez-Trujillo
Journal:  J Neurosci Methods       Date:  2018-04-22       Impact factor: 2.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.