Literature DB >> 6853102

Visual fields described by contrast sensitivity, by acuity, and by relative sensitivity to different orientations.

D Regan, K I Beverley.   

Abstract

Sinewave grating contrast sensitivity was measured as a function of eccentricity and azimuthal angle for four orientations of gratings whose spatial frequencies ranged from 2 to 20 c/deg. Visual fields for cutoff spatial frequency were also mapped. Log contrast sensitivity fell off approximately linearly with eccentricity for all azimuths. Orientational differences in contrast sensitivity varied irregularly over the visual field and, though small for central vision, could reach as high as 25 dB in localized patches at eccentricities greater than about 12 degrees.

Mesh:

Year:  1983        PMID: 6853102

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  18 in total

1.  Characterizing visual performance fields: effects of transient covert attention, spatial frequency, eccentricity, task and set size.

Authors:  M Carrasco; C P Talgar; E L Cameron
Journal:  Spat Vis       Date:  2001

2.  Estimation of spatial scale across the visual field using sinusoidal stimuli.

Authors:  Kelsey M Keltgen; William H Swanson
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-02-02       Impact factor: 4.799

3.  Coverage and the design of striate cortex.

Authors:  N V Swindale
Journal:  Biol Cybern       Date:  1991       Impact factor: 2.086

4.  Curvature detection in the visual field and a possible physiological correlate.

Authors:  M Fahle
Journal:  Exp Brain Res       Date:  1986       Impact factor: 1.972

5.  Visual resolution of macaque retinal ganglion cells.

Authors:  J M Crook; B Lange-Malecki; B B Lee; A Valberg
Journal:  J Physiol       Date:  1988-02       Impact factor: 5.182

6.  Low-contrast letter charts in early diabetic retinopathy, ocular hypertension, glaucoma, and Parkinson's disease.

Authors:  D Regan; D Neima
Journal:  Br J Ophthalmol       Date:  1984-12       Impact factor: 4.638

Review 7.  Acuity perimetry and glaucoma.

Authors:  C D Phelps
Journal:  Trans Am Ophthalmol Soc       Date:  1984

8.  Temporal attention improves perception similarly at foveal and parafoveal locations.

Authors:  Antonio Fernández; Rachel N Denison; Marisa Carrasco
Journal:  J Vis       Date:  2019-01-02       Impact factor: 2.240

9.  Isoeccentric locations are not equivalent: the extent of the vertical meridian asymmetry.

Authors:  Jared Abrams; Aaron Nizam; Marisa Carrasco
Journal:  Vision Res       Date:  2011-11-09       Impact factor: 1.886

10.  Balance between pattern and flicker sensitivities in the visual fields of ophthalmological patients.

Authors:  D Regan; D Neima
Journal:  Br J Ophthalmol       Date:  1984-05       Impact factor: 4.638

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.