Literature DB >> 6712907

Balance between pattern and flicker sensitivities in the visual fields of ophthalmological patients.

D Regan, D Neima.   

Abstract

We measured the balance between visual sensitivities to pattern and to flicker rather than measuring absolute sensitivities to pattern or flicker. The test target was a 2-cycle deg-1 sinewave grating that was counterphase modulated at 8 Hz. Seventeen points in the visual field were tested out to eccentricities of 24 degrees. We examined 10 control subjects, 6 patients with glaucoma 10 with ocular hypertension, and 10 with multiple sclerosis. For controls pattern sensitivity was lower than flicker sensitivity in central vision. The converse held in peripheral vision. The balance between pattern sensitivity and flicker sensitivity was markedly abnormal in part or all of the visual field for many patients. There were examples in all patient groups. In some patients flicker sensitivity was depressed relative to pattern. In others the converse was true. Of 10 patients with ocular hypertension and no perimetric field loss 8 had a significantly abnormal ratio between pattern sensitivity and flicker sensitivity at some point in the visual field. The balance between pattern and flicker sensitivity was more sensitive to visual pathology than absolute sensitivity to either pattern or flicker. We conclude that the relationship between pattern and flicker sensitivity may be more sensitive to visual field damage than is conventional perimetry or visual acuity perimetry.

Entities:  

Mesh:

Year:  1984        PMID: 6712907      PMCID: PMC1040329          DOI: 10.1136/bjo.68.5.310

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  16 in total

1.  The morphological types of ganglion cells of the domestic cat's retina.

Authors:  B B Boycott; H Wässle
Journal:  J Physiol       Date:  1974-07       Impact factor: 5.182

2.  Psychophysical evidence for sustained and transient detectors in human vision.

Authors:  J J Kulikowski; D J Tolhurst
Journal:  J Physiol       Date:  1973-07       Impact factor: 5.182

3.  Electrophysiological and psychophysical responses to modulation of contrast of a grating pattern.

Authors:  I Bodis-Wollner; C D Hendley; J J Kulikowski
Journal:  Perception       Date:  1972       Impact factor: 1.490

4.  Separate channels for the analysis of the shape and the movement of moving visual stimulus.

Authors:  D J Tolhurst
Journal:  J Physiol       Date:  1973-06       Impact factor: 5.182

5.  Flicker and pattern detection: a comparison of thresholds.

Authors:  U T Keesey
Journal:  J Opt Soc Am       Date:  1972-03

6.  Effect of eye movements on the contrast sensitivity of spatio-temporal patterns.

Authors:  J J Kulikowski
Journal:  Vision Res       Date:  1971-03       Impact factor: 1.886

7.  Fluorescein angiographic defects of the optic disc in glaucoma.

Authors:  B Schwartz; J C Rieser; S L Fishbein
Journal:  Arch Ophthalmol       Date:  1977-11

8.  Spatiotemporal modulation transfer in the human eye.

Authors:  F L van Nes; J J Koenderink; H Nas; M A Bouman
Journal:  J Opt Soc Am       Date:  1967-09

9.  Impaired temporal resolution of vision after acute retrobulbar neuritis.

Authors:  R J Galvin; D Regan; J R Heron
Journal:  Brain       Date:  1976-06       Impact factor: 13.501

10.  Interocular comparison of contrast sensitivities in glaucoma patients and suspects.

Authors:  A Atkin; M Wolkstein; I Bodis-Wollner; M Anders; B Kels; S M Podos
Journal:  Br J Ophthalmol       Date:  1980-11       Impact factor: 4.638

View more
  7 in total

1.  Spatial frequency-selective losses with pattern electroretinogram in type 1 (insulin-dependent) diabetic patients without retinopathy.

Authors:  M A Di Leo; B Falsini; S Caputo; G Ghirlanda; V Porciatti; A V Greco
Journal:  Diabetologia       Date:  1990-12       Impact factor: 10.122

2.  Association of Vistech contrast sensitivity and visual field findings in glaucoma.

Authors:  W E Sponsel; K L DePaul; J F Martone; M B Shields; A R Ollie; W C Stewart
Journal:  Br J Ophthalmol       Date:  1991-09       Impact factor: 4.638

3.  Spatial frequency processing and the prediction of reading ability: a preliminary investigation.

Authors:  W Lovegrove; W Slaghuis; A Bowling; P Nelson; E Geeves
Journal:  Percept Psychophys       Date:  1986-12

4.  Radial keratotomy and glare effects on contrast sensitivity.

Authors:  A Atkin; P Asbell; N Justin; H Smith; R Wayne; J Winterkorn
Journal:  Doc Ophthalmol       Date:  1986-02-28       Impact factor: 2.379

5.  Low-contrast letter charts in early diabetic retinopathy, ocular hypertension, glaucoma, and Parkinson's disease.

Authors:  D Regan; D Neima
Journal:  Br J Ophthalmol       Date:  1984-12       Impact factor: 4.638

6.  Pattern reversal retinal potentials in ocular hypertensives at high and low risk of developing glaucoma.

Authors:  G L Trick
Journal:  Doc Ophthalmol       Date:  1987-01       Impact factor: 2.379

7.  The Effect of Cataract on Early Stage Glaucoma Detection Using Spatial and Temporal Contrast Sensitivity Tests.

Authors:  Johann Klein; Barbara K Pierscionek; Jan Lauritzen; Karin Derntl; Andrzej Grzybowski; Margarita B Zlatkova
Journal:  PLoS One       Date:  2015-06-08       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.