Literature DB >> 6849261

Validation of the angiographic accuracy of digital left ventriculography.

A B Nichols, E C Martin, T P Fles, K M Stugensky, L A Balancio, W J Casarella, M B Weiss.   

Abstract

Digital subtraction angiography enhances the contrast to background signal, enabling the performance of angiography with reduced doses of contrast medium. The objectives of the present study were (1) to validate the accuracy of digital left ventriculography for measurement of left ventricular volumes and segmental contraction; and (2) to compare the hemodynamic effects resulting from low-and high-dose intraventricular contrast injections. Twenty-eight patients underwent digital left ventriculography, performed by intraventricular injection of 7 ml of contrast medium diluted in saline solution, followed by conventional cineangiography of the left ventricle performed with 45 ml of undiluted contrast medium. Left ventricular volumes calculated from digital ventriculograms correlated well with volumes calculated from conventional ventriculograms: end-diastolic volume (r = 0.97, standard error of estimate [SEE] 23.4 ml; end-systolic volume (r = 0.97, SEE 15.4 ml); stroke volume (r = 0.95, SEE 14.7 ml); and ejection fraction (r = 0.97, SEE 3.8%). Segmental left ventricular contraction, measured as percent chordal shortening of hemiaxes, correlated moderately well (r = 0.81, SEE 11.5%). After injection of undiluted contrast medium, left ventricular systolic pressure decreased (133 +/- 31 to 123.5 +/- 27 mm Hg; p less than 0.01) and left ventricular end-diastolic pressure increased (12.0 +/- 7 to 16.9 +/- 10 mm Hg; p less than 0.001). Left ventricular systolic and end-diastolic pressures did not change significantly after injection of diluted contrast medium, and patients had no discomfort. Thus, digital subtraction angiography permits the performance of left ventriculography with markedly reduced doses of contrast medium, obviating the hemodynamic effects resulting from injection of conventional doses of contrast medium. This new approach to left ventriculography provides high resolution ventriculograms for accurate measurement of left ventricular volumes, stroke volume, and ejection fraction.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6849261     DOI: 10.1016/s0002-9149(83)80040-x

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

1.  Cardiac applications of digital subtraction angiography.

Authors:  R A Vogel; G B Mancini; E R Bates
Journal:  Int J Card Imaging       Date:  1985

2.  Comparison of digital with conventional ventriculography for quantitative right ventricular studies.

Authors:  P E Lange; W Radtke; K E Fellows; D G Onnasch; P H Heintzen
Journal:  Cardiovasc Intervent Radiol       Date:  1988       Impact factor: 2.740

Review 3.  Left ventricular imaging by digital subtraction angiography.

Authors:  R A Vogel
Journal:  Int J Card Imaging       Date:  1988

4.  Investigation of left ventricular function by digital subtraction angiography.

Authors:  R A Greenbaum; T R Evans
Journal:  Br Heart J       Date:  1984-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.