Literature DB >> 6846167

Comparison of digital intravenous ventriculography with direct left ventriculography for quantitation of left ventricular volumes and ejection fractions.

S L Norris, R A Slutsky, J Mancini, W L Ashburn, G Gregoratos, K L Peterson, C B Higgins.   

Abstract

Digital images of the left ventricle obtained at 30 frames/second from continuous fluoroscopy after intravenous injection of contrast medium (digital intravenous ventriculography) were used to estimate left ventricular (LV) volumes and ejection fraction with use of several techniques for identifying the ventriculographic silhouette. The digital technique was compared with direct contrast left ventriculography in 26 patients undergoing diagnostic cardiac catheterization. End-diastolic and end-systolic volumes calculated from digital intravenous and direct left ventriculograms were obtained with use of a standard area-length formula. Both end-diastolic volume (EDV) (r = 0.88, y = 1.06x - 17.1 ml) and end-systolic volume (ESV) (r = 0.89, y = 0.96x + 0.43 ml) determined from digital intravenous ventriculography (mask mode images) correlated closely with those obtained by direct left ventriculography. Combining the EDV and ESV to define the relation between the 2 techniques yielded an even closer correlation (r = 0.96). There was also good correlation between the 2 techniques for measurement of ejection fraction (r = 0.81, standard error of the estimate 6.7%). Measurements from direct left ventriculography were frequently invalidated by ventricular arrhythmias during the time of opacification of the left ventricle; this was rarely the case for digital intravenous ventriculography. It is concluded that area-length estimates of LV volumes and ejection fraction can be accurately obtained from digital processing of fluoroscopic LV images after intravenous injection of contrast medium.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6846167     DOI: 10.1016/0002-9149(83)90319-3

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  7 in total

1.  Assessment of left ventricular performance during percutaneous transluminal coronary angioplasty: a study by intravenous digital subtraction ventriculography.

Authors:  M S Norell; J P Lyons; A H Gershlick; J E Gardener; M T Rothman; C A Layton; R Balcon
Journal:  Br Heart J       Date:  1988-04

2.  Cardiac applications of digital subtraction angiography.

Authors:  R A Vogel; G B Mancini; E R Bates
Journal:  Int J Card Imaging       Date:  1985

3.  Comparison of digital with conventional ventriculography for quantitative right ventricular studies.

Authors:  P E Lange; W Radtke; K E Fellows; D G Onnasch; P H Heintzen
Journal:  Cardiovasc Intervent Radiol       Date:  1988       Impact factor: 2.740

Review 4.  Left ventricular imaging by digital subtraction angiography.

Authors:  R A Vogel
Journal:  Int J Card Imaging       Date:  1988

5.  Cardiac imaging with digital subtraction angiography.

Authors:  G B Mancini; C B Higgins; S L Norris; R A Slutsky
Journal:  Cardiovasc Intervent Radiol       Date:  1983       Impact factor: 2.740

6.  Cardiac digital subtraction angiography: peripheral versus central intravenous dye injections.

Authors:  R Detrano; C Simpfendorfer; R McIntyre; E E Salcedo
Journal:  Cardiovasc Intervent Radiol       Date:  1985       Impact factor: 2.740

7.  [Digital subtraction angiocardiography--an alternative to traditional angiocardiography?].

Authors:  P Spiller; F K Schmiel
Journal:  Klin Wochenschr       Date:  1984-11-15
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.