Literature DB >> 6841710

Nuclear magnetic resonance (NMR) tomography of the central nervous system: comparison of two imaging sequences.

W Huk, W Heindel, M Deimling, E Stetter.   

Abstract

A brief description of a nuclear magnetic resonance (NMR) imaging system and preliminary results from its clinical evaluation in the study of various central nervous system diseases are presented. Particular attention is paid to NMR capabilities for soft tissue discrimination, topographical demarcation, and specificity of diagnosis. Two imaging sequences were used: (a) Spin echo measurements with four sets of imaging parameters revealed the different appearances of normal and pathological structures. (b) Inversion recovery images showed marked gray-white matter contrast and clear depiction of pathological lesions. Finally, a number of measurements of longitudinal (T1) and transverse (T2) relaxation times of normal and pathological tissues were carried out.

Entities:  

Mesh:

Year:  1983        PMID: 6841710     DOI: 10.1097/00004728-198306000-00016

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  7 in total

1.  Evaluation by MRI of paraparesis and tetraparesis of undiagnosed aetiology.

Authors:  E B Ringelstein; D Krieger; B Hünermann
Journal:  J Neurol       Date:  1987-08       Impact factor: 4.849

2.  The use of ultrasound during spinal cord surgery.

Authors:  J M Rubin; W F Chandler
Journal:  World J Surg       Date:  1987-10       Impact factor: 3.352

Review 3.  Magnetic resonance imaging (MRI): method and early clinical experiences in diseases of the central nervous system.

Authors:  W J Huk; G Gademann
Journal:  Neurosurg Rev       Date:  1984       Impact factor: 3.042

4.  Cerebral NMR: diagnostic evaluation of brain tumors by partial saturation technique with resistive NMR.

Authors:  R A Zimmerman; L T Bilaniuk; R I Grossman; H I Goldberg; W Edelstein; P Bottomley; R W Redington
Journal:  Neuroradiology       Date:  1985       Impact factor: 2.804

5.  Comparison of multi echo and contrast-enhanced MR scans: image contrast and delineation of intracranial tumors.

Authors:  W Schörner; M Laniado; W Kornmesser; R Felix
Journal:  Neuroradiology       Date:  1989       Impact factor: 2.804

6.  Balance of T1-weighted images before and after application of a paramagnetic substance (Gd-DTPA).

Authors:  W Müller; G Krämer; R G Röder; A Kühnert
Journal:  Neurosurg Rev       Date:  1987       Impact factor: 3.042

7.  Nuclear magnetic resonance imaging of the region of the sella turcica.

Authors:  W J Huk; R Fahlbusch
Journal:  Neurosurg Rev       Date:  1985       Impact factor: 3.042

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.