Literature DB >> 6827368

Accuracy of deconvolution algorithms assessed by simulation studies: concise communication.

A Kuruc, S Treves, J A Parker.   

Abstract

Deconvolution has been used to correct first-pass radionuclide angiocardiography for the time course of the delivery of radiopharmaceutical into the cardiopulmonary system. The extreme sensitivity of deconvolution to random errors in the data may account for some of the problems encountered in practice. We implemented several deconvolution algorithms that were suitable for use with the unimodal and multimodal superior vena caval and pulmonary curves found in left-to-right shunt quantification. The sensitivity of the algorithms to random errors was assessed using mathematical test problems degraded with pseudorandom noise. An algorithm that constrained the deconvolved pulmonary curve to be expressable as the non-negative sum of a set of lagged normal curves was found to have the smallest maximum error on the curves tested. Comparison with results from a previously published test problem indicated an error reduction of greater than 50% over previously used algorithms. Use of this algorithm may permit more accurate deconvolution of pulmonary time-activity curves and thereby improve shunt quantification.

Mesh:

Year:  1983        PMID: 6827368

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  5 in total

1.  Effects of statistical noise and digital filtering on the parameters calculated from the impulse response function.

Authors:  Z Szabó; L Nyitrai; C Sondhaus
Journal:  Eur J Nucl Med       Date:  1987

Review 2.  Model identification and estimation of organ-function parameters using radioactive tracers and the impulse-response function.

Authors:  Z Szabó; H Vosberg; C A Sondhaus; L E Feinendegen
Journal:  Eur J Nucl Med       Date:  1985

3.  Deconvolving out indicator smearing in the right ventricle facilitates left-to-right shunt quantitation.

Authors:  D Eterović; Z Dujić; S Popović
Journal:  Eur J Nucl Med       Date:  1994-06

4.  Hepatic disposition and biliary excretion of bilirubin and bilirubin glucuronides in intact rats. Differential processing of pigments derived from intra- and extrahepatic sources.

Authors:  J M Crawford; B J Ransil; C S Potter; S V Westmoreland; J L Gollan
Journal:  J Clin Invest       Date:  1987-04       Impact factor: 14.808

5.  The appended curve technique for deconvolutional analysis--method and validation.

Authors:  J E Juni; J H Thrall; J W Froelich; R C Wiggins; D A Campbell; M Tuscan
Journal:  Eur J Nucl Med       Date:  1988
  5 in total