Literature DB >> 3908109

Model identification and estimation of organ-function parameters using radioactive tracers and the impulse-response function.

Z Szabó, H Vosberg, C A Sondhaus, L E Feinendegen.   

Abstract

Examination of the input-output events in functioning organs by the use of the impulse-response function (IRF) for a radioactive tracer is gaining more and more ground in nuclear medicine. This study summarizes the development of deconvolution analysis, laying special stress on the 'model-free' approach. System linearity and time invariance are discussed, and means of eliminating noise in IRFs originating from the input and organ-time-activity curves are outlined. Typical IRFs are illustrated by flow diagrams, time-domain curves, and their representation by Laplace transforms. The cases of nondiffusible and diffusible tracers as well as parenchymally extracted and transported substances are discussed. Methods for the derivation of models and for the calculation of physiologically important parameters from the IRFs are suggested.

Mesh:

Substances:

Year:  1985        PMID: 3908109     DOI: 10.1007/bf00279082

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  63 in total

1.  Theory of the measurement of blood flow by the dilution of an indicator.

Authors:  J L STEPHENSON
Journal:  Bull Math Biophys       Date:  1948-09

Review 2.  Basic concepts of radiocardiography.

Authors:  L Donato
Journal:  Semin Nucl Med       Date:  1973-04       Impact factor: 4.446

3.  Mathematical analysis of circulatory mixing process.

Authors:  A Kamiya; T Togawa
Journal:  Bull Math Biol       Date:  1973-06       Impact factor: 1.758

4.  Pulmonary to arterial circulatory transfer function: importance in respiratory control.

Authors:  R L Lange; J D Horgan; J T Botticelli; T Tsagaris; R P Carlisle; H Kuida
Journal:  J Appl Physiol       Date:  1966-07       Impact factor: 3.531

5.  Validation of simple and complex models in physiology and medicine.

Authors:  C Cobelli; E R Carson; L Finkelstein; M S Leaning
Journal:  Am J Physiol       Date:  1984-02

6.  Comparison of two optimizing algorithms for cerebral blood flow analysis using the intravenous 133Xe wash-out method.

Authors:  M A Pitänen; J T Kuikka; H Kiiliäinen; D J Macey
Journal:  Int J Biomed Comput       Date:  1982-05

7.  Regional cerebral blood flow measurements by 133Xe-inhalation: methodology and applications in neuropsychology and psychiatry.

Authors:  J Risberg
Journal:  Brain Lang       Date:  1980-01       Impact factor: 2.381

8.  rCBF measurements by 133Xe inhalation: recent methodological advances.

Authors:  J Risberg; I Prohovnik
Journal:  Prog Nucl Med       Date:  1981

9.  Advances in computer technology: software, hardware and overall perspectives.

Authors:  J G Llaurado
Journal:  Int J Biomed Comput       Date:  1982-09

10.  Two closed two-compartment models with time-delay.

Authors:  L E Johnson
Journal:  IEEE Trans Biomed Eng       Date:  1980-11       Impact factor: 4.538

View more
  7 in total

1.  Effects of statistical noise and digital filtering on the parameters calculated from the impulse response function.

Authors:  Z Szabó; L Nyitrai; C Sondhaus
Journal:  Eur J Nucl Med       Date:  1987

2.  Future direction of renal positron emission tomography.

Authors:  Zsolt Szabo; Jinsong Xia; William B Mathews; Phillip R Brown
Journal:  Semin Nucl Med       Date:  2006-01       Impact factor: 4.446

Review 3.  Molecular imaging of the kidneys.

Authors:  Zsolt Szabo; Nada Alachkar; Jinsong Xia; William B Mathews; Hamid Rabb
Journal:  Semin Nucl Med       Date:  2011-01       Impact factor: 4.446

4.  PET Imaging of the AT1 receptor with [11C]KR31173.

Authors:  Tamas G Zober; William B Mathews; Esen Seckin; Sung-Eun Yoo; John Hilton; Jinsong Xia; Kathryn Sandberg; Hayden T Ravert; Robert F Dannals; Zsolt Szabo
Journal:  Nucl Med Biol       Date:  2006-01       Impact factor: 2.408

5.  Kinetic analysis of [11C]McN5652: a serotonin transporter radioligand.

Authors:  Z Szabo; U Scheffel; W B Mathews; H T Ravert; K Szabo; M Kraut; S Palmon; G A Ricaurte; R F Dannals
Journal:  J Cereb Blood Flow Metab       Date:  1999-09       Impact factor: 6.200

6.  Characterization of toxicokinetics and toxicodynamics with linear systems theory: application to lead-associated cognitive decline.

Authors:  J M Links; B S Schwartz; D Simon; K Bandeen-Roche; W F Stewart
Journal:  Environ Health Perspect       Date:  2001-04       Impact factor: 9.031

7.  A comparison of deconvolution and the Rutland-Patlak plot in parenchymal renal uptake rate.

Authors:  Issa A Al-Shakhrah
Journal:  Indian J Nucl Med       Date:  2012-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.