Literature DB >> 6826706

Single radial hemolysis test for rubella immunity and recent infection.

P W Neumann, J M Weber.   

Abstract

The single radial hemolysis (SRH) test was compared with the hemagglutination inhibition (HI) test for establishing rubella immune status and diagnosing recent infection. Correlation between mean SRH diameters and HI titers greater than or equal to 1:8 was high (R = 0.99). It is suggested that a level of greater than or equal to 5 IU represents low-level antibody and that greater than or equal to 15 IU is a conservative threshold for designation of immunity. Of 343 sera tested, only 1 false-positive was found by SRH with the 5 IU cutoff level. The SRH test could detect serum antibody levels as low as 2.5 IU, whereas 15 IU was generally the limit of resolution of the HI test. Data from sucrose density gradient fractionation of serum demonstrated that neither rubella-specific immunoglobulin M (IgM) nor early postinfection HI-reactive IgG was detected by SRH. However, diagnostic changes in antibody titer measured by SRH were in general greater than those measured by HI. The SRH test showed diagnostic titer changes in some sera containing specific IgM for which no such changes were detected by the HI test. A 2.5-mm difference in hemolytic zone diameters (a fourfold rise in international units) between acute- and convalescent-phase serum pairs was chosen as being of diagnostic significance. This difference was less than the minimum observed difference of 2.9 mm from 59 serum pairs showing diagnostic changes by HI and far exceeded (greater than 3.6 standard deviations) the within-test and individual variability seen for 95 pregnant women from whom samples were obtained during each trimester.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6826706      PMCID: PMC272568          DOI: 10.1128/jcm.17.1.28-34.1983

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  19 in total

1.  Application of the passive haemolysis test for the determination of rubella virus antibodies.

Authors:  K Skaug; I Orstavik; J C Ulstrup
Journal:  Acta Pathol Microbiol Scand B       Date:  1975-08

2.  Hemolysis-in-gel test for the demonstration of antibodies to rubella virus.

Authors:  O Strannegård; L Grillner; I M Lindberg
Journal:  J Clin Microbiol       Date:  1975-06       Impact factor: 5.948

3.  Center for Disease Control Diagnostic Immunology Proficiency Testing Program results for 1977.

Authors:  R N Taylor; K M Fulford; V A Przybyszewski; V Pope
Journal:  J Clin Microbiol       Date:  1978-10       Impact factor: 5.948

4.  Evaluation of the single radial haemolysis (SRH) technique for rubella antibody measurement.

Authors:  S M Russell; S R Benjamin; M Briggs; M Jenkins; P P Mortimer; S B Payne
Journal:  J Clin Pathol       Date:  1978-06       Impact factor: 3.411

5.  An assessment of radial haemolysis in the detection of rubella antibody.

Authors:  B Gee; B E Jordan; P R Mortimer
Journal:  J Clin Pathol       Date:  1978-01       Impact factor: 3.411

6.  DTT test: a new method to differentiate IgM and IgG erythrocyte antibodies.

Authors:  B Pirofsky; E R Rosner
Journal:  Vox Sang       Date:  1974       Impact factor: 2.144

7.  Rubella hemagglutinin prepared with alkaline extraction of virus grown in suspension culture of BHK-21 cells.

Authors:  P E Halonen; J M Ryan; J A Stewart
Journal:  Proc Soc Exp Biol Med       Date:  1967-05

8.  Single-radial hemolysis as a cost-effective determinant of Rubella antibody status.

Authors:  J M Forger; R F Gilfillan
Journal:  J Clin Microbiol       Date:  1979-01       Impact factor: 5.948

9.  Rubella antibody measured by radial haemolysis. Characteristics and performance of a simple screening method for use in diagnostic laboratories.

Authors:  J B Kurtz; P P Mortimer; P R Mortimer; P Morgan-Capner; M S Shafi; G B White
Journal:  J Hyg (Lond)       Date:  1980-04

10.  Single-radial-hemolysis test for the assay of rubella antibody in antenatal, vaccinated, and rubella virus-infected patients.

Authors:  G B Harnett; C A Palmer; E M Mackay-Scollay
Journal:  J Infect Dis       Date:  1979-12       Impact factor: 5.226

View more
  4 in total

1.  Serological study of the epidemiology of mumps virus infection in north-west England.

Authors:  D J Nokes; J Wright; P Morgan-Capner; R M Anderson
Journal:  Epidemiol Infect       Date:  1990-08       Impact factor: 2.451

2.  Accuracy of single radial hemolysis test for rubella immunity when internal reference standards are used to estimate antibody levels.

Authors:  F E Nommensen
Journal:  J Clin Microbiol       Date:  1987-01       Impact factor: 5.948

3.  Rubella epidemiology in South East England.

Authors:  D J Nokes; R M Anderson; M J Anderson
Journal:  J Hyg (Lond)       Date:  1986-04

4.  Diagnosis of postnatally acquired rubella by use of three enzyme-linked immunosorbent assays for specific immunoglobulins G and M and single radial hemolysis for specific immunoglobulin G.

Authors:  P R Field; C M Gong
Journal:  J Clin Microbiol       Date:  1984-11       Impact factor: 5.948

  4 in total