An assessment of radial haemolysis in the detection of rubella antibody.

B Gee, B E Jordan, P R Mortimer.   

Abstract

The results obtained by radial haemolysis in the detection of antibodies to rubella virus compared well with those obtained by haemagglutination inhibition. Radial haemolysis is unaffected by non-specific inhibitors. The sera do not therefore require pretreatment and the results are less equivocal. Radial haemolysis appears to be as sensitive as immunofluorescence and floatation centrifugation. It is possible to examine large numbers of sera with a considerable saving of time compared with the traditional haemagglutination technique. Rheumatoid factor may cause interference in radial haemolysis. Immune sera may be recorded as non-immune. This interference can be removed by 2-mercaptoethanol or reduced by heating sera at 60 degrees C for 20 minutes.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 342547      PMCID: PMC476715          DOI: 10.1136/jcp.31.1.35

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  6 in total

1.  Application of the passive haemolysis test for the determination of rubella virus antibodies.

Authors:  K Skaug; I Orstavik; J C Ulstrup
Journal:  Acta Pathol Microbiol Scand B       Date:  1975-08

2.  Hemolysis-in-gel test for the demonstration of antibodies to rubella virus.

Authors:  O Strannegård; L Grillner; I M Lindberg
Journal:  J Clin Microbiol       Date:  1975-06       Impact factor: 5.948

3.  Single-radial-hemolysis: a new method for the assay of antibody to influenza haemagglutinin. Applications for diagnosis and seroepidemiologic surveillance of influenza.

Authors:  G C Schild; M S Pereira; P Chakraverty
Journal:  Bull World Health Organ       Date:  1975       Impact factor: 9.408

4.  Rubella-virus hemagglutination-inhibition test.

Authors:  G L Stewart; P D Parkman; H E Hopps; R D Douglas; J P Hamilton; H M Meyer
Journal:  N Engl J Med       Date:  1967-03-09       Impact factor: 91.245

5.  Evaluation of the hemolysis-in-gel test for the screening of rubella immunity and the demonstration of recent infection.

Authors:  L Grillner; O Strannegård
Journal:  J Clin Microbiol       Date:  1976-02       Impact factor: 5.948

6.  Use of trypsin-modified human erythrocytes in rubella hemagglutination-inhibition testing.

Authors:  E P Quirin; D B Nelson; S L Inhorn
Journal:  Appl Microbiol       Date:  1972-09
  6 in total
  2 in total

1.  A comparison of three tests for rubella antibody screening.

Authors:  P Morgan-Capner; H J Pullen; J R Pattison; D E Bidwell; A Bartlett; A Voller
Journal:  J Clin Pathol       Date:  1979-06       Impact factor: 3.411

2.  Single radial hemolysis test for rubella immunity and recent infection.

Authors:  P W Neumann; J M Weber
Journal:  J Clin Microbiol       Date:  1983-01       Impact factor: 5.948

  2 in total