Literature DB >> 6808014

Microtube coagulase test for detection of coagulase-positive staphylococci.

J Goldstein, J W Roberts.   

Abstract

Studies were performed to determine the sensitivity and specificity of a new microtube method for the detection of coagulase production by Staphylococcus aureus. Rabbit plasma containing EDTA was added to and lyophilized in API microtubes. Two standard coagulase plasmas containing EDTA were used in the conventional macrotube test and served as a basis for comparison. No false-positive or false-negative reactions were encountered with the microtube system. With this system, 53% of the coagulase-positive strains tested were detected within 1 h after inoculation, 82% were detected after 2 h, 97% were detected after 3 h, and 99% were detected after 4 h. With the first conventional method, 45, 81, 96, and 98% of the positive strains were detected in 1, 2, 3, and 4 h, respectively, whereas with the second conventional method, only 6% of the positive strains were detected in 1 h, 24% in 2 h, 66% in 3 h, and 81% in 4 h. With the microtube method, 5 of the 139 coagulase-producing strains studied reverted to negative between 5 and 24 h after inoculation, whereas 9 reverted with the more rapid conventional method, and no reversions occurred with the second conventional method. All reversions involved strains which caused gelation of plasma within 1 h after inoculation. The data obtained showed that 99% of the coagulase-positive strains tested could be detected within 4 h by the microtube method. In addition, the microtube method offers a more convenient and economical format for the performance of the coagulase tube test.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 6808014      PMCID: PMC272200          DOI: 10.1128/jcm.15.5.848-851.1982

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  8 in total

1.  Evidence for two forms of staphylococcal coagulase.

Authors:  E S DUTHIE
Journal:  J Gen Microbiol       Date:  1954-06

2.  Protease from Staphyloccus aureus.

Authors:  G R Drapeau
Journal:  Methods Enzymol       Date:  1976       Impact factor: 1.600

3.  Coagulase and Hemolysin Tests as Measures of the Pathogenicity of Staphylococci.

Authors:  G H Chapman; C Berens; A Peters; L Curcio
Journal:  J Bacteriol       Date:  1934-10       Impact factor: 3.490

4.  [Improving the Ivan Hall tube for the study in series of growth and physiology of bacteria].

Authors:  J Buissière
Journal:  C R Acad Hebd Seances Acad Sci D       Date:  1972-02-28

5.  Activation of a pro-enzyme by a stoichiometric reaction with another protein. The reaction between prothrombin and staphylocoagulase.

Authors:  H C Hemker; B M Bas; A D Muller
Journal:  Biochim Biophys Acta       Date:  1975-01-30

6.  Comparison of animal sera for suitability in coagulase testing.

Authors:  D S Orth; L R Chugg; A W Anderson
Journal:  Appl Microbiol       Date:  1971-03

7.  Evaluation of three test procedures for identification of Staphylococcus aureus from clinical sources.

Authors:  J Y Zarzour; E A Belle
Journal:  J Clin Microbiol       Date:  1978-02       Impact factor: 5.948

8.  PLASMA COAGULATION BY ORGANISMS OTHER THAN STAPHYLOCOCCUS AUREUS.

Authors:  B G BAYLISS; E R HALL
Journal:  J Bacteriol       Date:  1965-01       Impact factor: 3.490

  8 in total
  5 in total

1.  Evaluation of the Staph-Ident and STAPHase systems for identification of staphylococci from bovine intramammary infections.

Authors:  J L Watts; J W Pankey; S C Nickerson
Journal:  J Clin Microbiol       Date:  1984-09       Impact factor: 5.948

2.  Inoculum size and lot-to-lot variation as significant variables in the tube coagulase test for Staphylococcus aureus.

Authors:  S T Selepak; F G Witebsky
Journal:  J Clin Microbiol       Date:  1985-11       Impact factor: 5.948

3.  Comparison of two commercially available test methods with conventional coagulase tests for identification of Staphylococcus aureus.

Authors:  D L Jungkind; N J Torhan; K E Corman; J M Bondi
Journal:  J Clin Microbiol       Date:  1984-02       Impact factor: 5.948

4.  Comparison of the Staphylococcus QuickFISH BC test with the tube coagulase test performed on positive blood cultures for evaluation and application in a clinical routine setting.

Authors:  E Carretto; M Bardaro; G Russello; M Mirra; C Zuelli; D Barbarini
Journal:  J Clin Microbiol       Date:  2012-10-24       Impact factor: 5.948

5.  Staphylococcus aureus aggregation in the plasma fraction of silkworm hemolymph.

Authors:  Hiroki Ryuno; Fuki Nigo; Isao Naguro; Kazuhisa Sekimizu; Chikara Kaito
Journal:  PLoS One       Date:  2019-05-30       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.