Literature DB >> 6806103

Quantification of the distribution of 111In-labelled platelets in organs.

P C van Reenen, M G Lötter, A D Heyns, F de Kock, C Herbst, H Kotzé, H Pieters, P C Minnaar, P N Badenhorst.   

Abstract

A single and practical approach to the in vivo quantification of 111indium-oxine labelled blood platelets with a scintillation camera and computer assisted imaging system was evaluated. Radioactivity of the 172 and 247 keV energies was measured in a phantom at various source distances from the collimator and the accuracy of anterior and posterior mode measurements compared with that of the geometrical mean (GM) method, with and without correction for Compton scatter (CS). Organ radioactivity, expressed as a percentage of whole body radioactivity, was determined in vivo in five baboons and the accuracy of the methods verified by post mortem quantification in the animals. Measurements in the anterior mode significantly overestimates hepatic and underestimates splenic radioactivity; posterior mode quantification reverses these results. Correction with the GM method made the accuracy and reproducibility very acceptable. Further correction for anterior-posterior attenuation and/or CS did not improve results materially. The GM method could readily be applied in five human subjects. This study showed that the GM method is an accurate and practical method for the in vivo quantification of organ and regional distribution of 111In-labelled platelets.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 6806103     DOI: 10.1007/BF00251649

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  12 in total

1.  In vivo quantitation of lesion radioactivity using external counting methods.

Authors:  S R Thomas; H R Maxon; J G Kereiakes
Journal:  Med Phys       Date:  1976 Jul-Aug       Impact factor: 4.071

2.  Recommended methods for radioisotope platelet survival studies: by the panel on Diagnostic Application of Radioisotopes in Hematology, International Committee for Standardization in Hematology.

Authors: 
Journal:  Blood       Date:  1977-12       Impact factor: 22.113

3.  A technique for the absolute measurement of activity using a gamma camera and computer.

Authors:  J S Fleming
Journal:  Phys Med Biol       Date:  1979-01       Impact factor: 3.609

4.  In vivo quantitation of radioactivity using the Anger camera.

Authors:  L S Graham; R Neil
Journal:  Radiology       Date:  1974-08       Impact factor: 11.105

5.  Indium-LLL labeled platelets: studies on preparation and evaluation of in vitro and in vivo functions.

Authors:  M L Thakur; M J Welch; J H Joist; R E Coleman
Journal:  Thromb Res       Date:  1976-10       Impact factor: 3.944

6.  Radiation dose from human platelets labelled with indium 111.

Authors:  O R van Reenen; M G Lötter; P C Minnaar; A du P Heyns; P N Badenhorst; H Pieters
Journal:  Br J Radiol       Date:  1980-08       Impact factor: 3.039

7.  Preparation of a viable population of indium-111-labelled human blood platelets.

Authors:  A D Heyns; P N Badenhorst; H Pieters; M G Lötter; P C Minnaar; L J Duyvené de Wit; O R Van Reenen; F P Retief
Journal:  Thromb Haemost       Date:  1980-02-29       Impact factor: 5.249

8.  Quantitative organ-uptake measurement with a gamma camera.

Authors:  A Ferrant; F Cauwe
Journal:  Eur J Nucl Med       Date:  1979-06-01

9.  Kinetics and in vivo redistribution of (111)Indium-labelled human platelets after intravenous protamine sulphate.

Authors:  A D Heyns; M G Lötter; P N Badenhorst; H Kotze; F C Killian; C Herbst; O R van Reenen; P C Minnaar
Journal:  Thromb Haemost       Date:  1980-10-31       Impact factor: 5.249

10.  Kinetics, distribution, and sites of destruction of canine blood platelets with In-111 oxine.

Authors:  M G Lötter; P N Badenhorst; A D Heyns; O R Van Reenen; H Pieters; P C Minnaar
Journal:  J Nucl Med       Date:  1980-01       Impact factor: 10.057

View more
  11 in total

1.  Effects of shortened acquisition time on accuracy and precision of quantitative estimates of organ activity.

Authors:  Bin He; Eric C Frey
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

2.  Comparison of residence time estimation methods for radioimmunotherapy dosimetry and treatment planning--Monte Carlo simulation studies.

Authors:  B He; R L Wahl; Y Du; G Sgouros; H Jacene; I Flinn; E C Frey
Journal:  IEEE Trans Med Imaging       Date:  2008-04       Impact factor: 10.048

3.  Abdominal SPECT/MRI fusion applied to the study of splenic and hepatic uptake of radiolabeled thrombocytes and colloids.

Authors:  H K Pohjonen; S E Savolainen; P H Nikkinen; V P Poutanen; E T Korppi-Tommola; B K Liewendahl
Journal:  Ann Nucl Med       Date:  1996-11       Impact factor: 2.668

4.  Activity estimation in radioimmunotherapy using magnetic nanoparticles.

Authors:  Samira Rasaneh; Hossein Rajabi; Fariba Johari Daha
Journal:  Chin J Cancer Res       Date:  2015-04       Impact factor: 5.087

5.  An improved method for the quantification of the in vivo kinetics of a representative population of 111In-labelled human platelets.

Authors:  P Wessels; A D Heyns; H Pieters; M G Lötter; P N Badenhorst
Journal:  Eur J Nucl Med       Date:  1985

6.  Analysis of scintigrams by singular value decomposition (SVD) technique.

Authors:  S E Savolainen; B K Liewendahl
Journal:  Ann Nucl Med       Date:  1994-05       Impact factor: 2.668

7.  Evaluation of quantitative imaging methods for organ activity and residence time estimation using a population of phantoms having realistic variations in anatomy and uptake.

Authors:  Bin He; Yong Du; W Paul Segars; Richard L Wahl; George Sgouros; Heather Jacene; Eric C Frey
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

8.  Estimates of radiation-absorbed dose to kidneys in patients treated with 90Y-ibritumomab tiuxetan.

Authors:  Sébastien Baechler; Robert F Hobbs; Andrew R Prideaux; Mélanie Recordon; Angelika Bischof-Delaloye; George Sgouros
Journal:  Cancer Biother Radiopharm       Date:  2008-10       Impact factor: 3.099

9.  Mechanisms of thrombocytopenia in chronic autoimmune thrombocytopenic purpura. Evidence of both impaired platelet production and increased platelet clearance.

Authors:  P J Ballem; G M Segal; J R Stratton; T Gernsheimer; J W Adamson; S J Slichter
Journal:  J Clin Invest       Date:  1987-07       Impact factor: 14.808

10.  Transpulmonary passage of 99mTc macroaggregated albumin in healthy humans at rest and during maximal exercise.

Authors:  Andrew T Lovering; Hans C Haverkamp; Lee M Romer; John S Hokanson; Marlowe W Eldridge
Journal:  J Appl Physiol (1985)       Date:  2009-04-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.