Error analysis for the determination of cerebral blood flow with the continuous inhalation of 15O-labeled carbon dioxide and positron emission tomography.

S C Jones, J H Greenberg, M Reivich.   

Abstract

The inhalation of C15O2 can be used for determining local cerebral blood flow (LCBF) using a quantitative model. The determination of LCBF in three dimensions using positron emission tomography (PET) involves errors due to counting statistics, data manipulation, and the estimation of parameters in the mathematical model. This work examines error propagation and its relation to the radiation dose to the subject's lungs. An expression has been derived for the root mean square uncertainty in LCBF as a function of LCBF, the spatial resolution and the sensitivity of PET instrument, the normal variability in the brain-blood partition coefficient for water, and absorbed radiation dose to the subject's lungs. The error in LCBF increases as CBF increases. At a normal cortical LCBF of 80 ml/100 g-m and a PET instrument with a 1.65 cm FWHM resolution, and a 46,000 cps per microCi/g sensitivity per slice, an error (coefficient of variation) of 5% results from an inhaled activity of 250 mCi, resulting in a lung dose of 5 rads, the maximum permissible dose allowed. For a more acceptable dose of 1.2 rads, the error is 7%. At a higher resolution (0.8 cm FWHM) and lower sensitivity (15,000 cps per microCi/g per slice), errors become on the order of 28% for a lung dose of 1.2 rads. Errors due to other factors such as blood sample counting, and instrument cross calibration can be virtually eliminated by proper technical strategies. This consideration of error and its relation to radiation dose is important for the application of this inhalation technique for the quantification of LCBF.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 6802887     DOI: 10.1097/00004728-198202000-00020

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  5 in total

1.  Imaging local cerebral blood flow by Xenon-enhanced computed tomography--technical optimization procedures.

Authors:  J S Meyer; T Shinohara; A Imai; M Kobari; F Sakai; T Hata; W T Oravez; G M Timpe; T Deville; E Solomon
Journal:  Neuroradiology       Date:  1988       Impact factor: 2.804

2.  Gradient effects in extravascular water determination using 15O-labelled water under steady state conditions: theory and error sensitivity.

Authors:  G J Meyer; O Schober; H Hundeshagen
Journal:  Eur J Nucl Med       Date:  1985

Review 3.  Positron emission tomography.

Authors:  Y L Yamamoto; C J Thompson; M Diksic; E Meyer; W H Feindel
Journal:  Neurosurg Rev       Date:  1984       Impact factor: 3.042

Review 4.  Positron emission tomography and in vivo measurements of tumour perfusion and oxygen utilisation.

Authors:  A A Lammertsma
Journal:  Cancer Metastasis Rev       Date:  1987       Impact factor: 9.264

5.  Dosimetry of intravenously administered oxygen-15 labelled water in man: a model based on experimental human data from 21 subjects.

Authors:  T Smith; C Tong; A A Lammertsma; K R Butler; L Schnorr; J D Watson; S Ramsay; J C Clark; T Jones
Journal:  Eur J Nucl Med       Date:  1994-10
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.