Literature DB >> 6802352

Blood gas analysis: effect of air bubbles in syringe and delay in estimation.

C K Biswas, J M Ramos, B Agroyannis, D N Kerr.   

Abstract

Two common sources of error in blood pH and blood gas analysis were studied. The effect of delay in estimation was studied in 10 volunteers and 40 patients. Syringes were stored at 0 degree C, (crushed ice), 4 degrees C (refrigerator) and 22 degrees C (room temperature). The pressure of oxygen (PO2) fell significantly by 20 minutes at 4 degrees C and 22 degrees C but did not change significantly at 0 degree C for up to 30 minutes. Blood pH, pressure of carbon dioxide (PCO2), and base excess did not change significantly for up to 30 minutes at 4 degrees C and 22 degrees C and up to 60 minutes at 0 degrees C. The effect of air bubbles in the syringe was studied by leaving a single bubble or froth in contact with the blood for one to five minutes in 40 patients. Po2 rose significantly after two minutes' contact with froth and two minutes' contact with the air bubble, and PCO2 fell significantly after three minutes' contact with the air bubble. Size of the bubble had little effect on rates of change. Blood pH, bicarbonate, TCO2, and base excess did not change significantly after up to five minutes' contact. For accurate estimation of PO2 and PCO2 it is necessary to avoid frothing, to expel all air bubbles within two minutes, and to inject the sample into the machine within 10 minutes or store the syringe in crushed ice. The requirements for blood pH and base excess measurement are less exacting.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 6802352      PMCID: PMC1496510          DOI: 10.1136/bmj.284.6320.923

Source DB:  PubMed          Journal:  Br Med J (Clin Res Ed)        ISSN: 0267-0623


  8 in total

1.  Sampling and storing of blood for determination of acid-base status.

Authors:  O S ANDERSEN
Journal:  Scand J Clin Lab Invest       Date:  1961       Impact factor: 1.713

2.  Regional quality control survey of blood-gas analysis.

Authors:  B D Minty; J F Nunn
Journal:  Ann Clin Biochem       Date:  1977-09       Impact factor: 2.057

3.  The effects of air bubbles and time delay on blood gas analysis.

Authors:  S Ishikawa; A Fornier; C Borst; M S Segal
Journal:  Ann Allergy       Date:  1974-08

4.  Errors in the measurement of blood P CO2 due to dilution of the sample with heparin solution.

Authors:  J G Bradley
Journal:  Br J Anaesth       Date:  1972-02       Impact factor: 9.166

5.  Titratable acid or base of body fluids.

Authors:  O Siggaard-Andersen
Journal:  Ann N Y Acad Sci       Date:  1966-04-01       Impact factor: 5.691

6.  Air bubbles and temperature effect on blood gas analysis.

Authors:  G Madiedo; R Sciacca; L Hause
Journal:  J Clin Pathol       Date:  1980-09       Impact factor: 3.411

7.  pH and blood-gas analysis. Methods of measurement and sources of error using electrode systems.

Authors:  A P Adams; J O Morgan-Hughes; M K Sykes
Journal:  Anaesthesia       Date:  1967-10       Impact factor: 6.955

8.  Nomograms for correction of blood Po2, Pco2, pH, and base excess for time and temperature.

Authors:  G R Kelman; J F Nunn
Journal:  J Appl Physiol       Date:  1966-09       Impact factor: 3.531

  8 in total
  17 in total

Review 1.  Use of umbilical cord blood gas analysis in the assessment of the newborn.

Authors:  L Armstrong; B J Stenson
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2007-11       Impact factor: 5.747

Review 2.  Practical points in the application of oxygen transport principles.

Authors:  P Nightingale
Journal:  Intensive Care Med       Date:  1990       Impact factor: 17.440

3.  [Optimization of blood gas analysis in intensive care units : Reduction of preanalytical errors and improvement of workflow].

Authors:  M Kieninger; N Zech; Y Mulzer; S Bele; M Seemann; H Künzig; A Schneiker; M Gruber
Journal:  Anaesthesist       Date:  2015-04-21       Impact factor: 1.041

4.  Comparison of Two New Generation Pulse Oximeters with Arterial Oxygen Saturation in Critically Ill Children: Correspondence.

Authors:  Viswas Chhapola; Sandeep Kumar Kanwal
Journal:  Indian J Pediatr       Date:  2015-05-14       Impact factor: 1.967

5.  ARTP statement on pulmonary function testing 2020.

Authors:  Karl Peter Sylvester; Nigel Clayton; Ian Cliff; Michael Hepple; Adrian Kendrick; Jane Kirkby; Martin Miller; Alan Moore; Gerrard Francis Rafferty; Liam O'Reilly; Joanna Shakespeare; Laurie Smith; Trefor Watts; Martyn Bucknall; Keith Butterfield
Journal:  BMJ Open Respir Res       Date:  2020-07

6.  Measurement of total CO2 in microliter samples of urine and other biological fluids using infrared detection of CO2.

Authors:  Francesco Trepiccione; Francesco Maria Iena; Laura Catalini; Francesco Martino Carpi; Mogens Koed; Sebastian Frische
Journal:  Pflugers Arch       Date:  2017-06-05       Impact factor: 3.657

7.  Too much heparin: possible source of error in blood gas analysis.

Authors:  A S Hutchison; S H Ralston; F J Dryburgh; M Small; I Fogelman
Journal:  Br Med J (Clin Res Ed)       Date:  1983-10-15

8.  Is it necessary to transport arterial blood samples on ice for pH and gas analysis?

Authors:  A A Nanji; K J Whitlow
Journal:  Can Anaesth Soc J       Date:  1984-09

9.  [The measurement of pH and gases in the blood using microanalysis: the effect of storage at 4 degrees C for an hour. A study in the rat].

Authors:  J H Gaudy; J F Sicard; M Quignon
Journal:  Can J Anaesth       Date:  1992-10       Impact factor: 5.063

10.  Prescription of oxygen concentrators for long term oxygen treatment: reassessment in one district.

Authors:  M J Walshaw; R Lim; C C Evans; C R Hind
Journal:  BMJ       Date:  1988-10-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.