Literature DB >> 6802168

Value of the simultaneous determination of PCO2 in monitoring exposure to 1,1,1-trichloroethane by breath analysis.

M Guillemin, E Gubéran.   

Abstract

Eight volunteers were exposed for eight hours to about 200 ppm of 1,1,1-trichloroethane. On the next morning five series of five alveolar samples were collected for the simultaneous determination of PCO2 and 1,1,1-trichloroethane concentration. Three different methods of sampling were used: voluntary hyperventilation, 10-s breathholding, and "standard." A linear relationship between the alveolar concentrations of both gases was observed in all subjects. Expired air was also collected in two subjects and an analogous relationship was observed. Also the Bohr dead space was found to be of similar size for CO2 and for 1,1,1-trichloroethane. In the monitoring of solvent exposure by breath analysis it is suggested that the results should be corrected for hyperventilation or hypoventilation and for dilution of alveolar air with dead space air by a proportional adjustment of the solvent concentration at the mean normal adveolar PCO2 or by disregarding the samples with a PCO2 outside normal range. The PCO2 determination in 40 unselected workers has shown that in more than a third of them, to monitor exposure by breath analysis would have been of little meaning without such an adjustment or rejection criteria.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 6802168      PMCID: PMC1008964          DOI: 10.1136/oem.39.2.161

Source DB:  PubMed          Journal:  Br J Ind Med        ISSN: 0007-1072


  11 in total

1.  The avoidance of biologic variables in breath tests for alcohol in blood.

Authors:  J C SMITH
Journal:  Am J Clin Pathol       Date:  1959-07       Impact factor: 2.493

2.  Physiological dead space and alveolar gas pressures at rest and during muscular exercise.

Authors:  E ASMUSSEN; M NIELSEN
Journal:  Acta Physiol Scand       Date:  1956-12-29

3.  Control of industrial exposure to tetrachloroethylene by measuring alveolar concentrations: theoretical approach using a mathematical model.

Authors:  E Guberan; J Fernandez
Journal:  Br J Ind Med       Date:  1974-04

Review 4.  Breath-alcohol analysis: uses, methods, and some forensic problems--review and opinion.

Authors:  M F Mason; K M Dubowski
Journal:  J Forensic Sci       Date:  1976-01       Impact factor: 1.832

5.  Solvent exposure in a shoe upper factory.

Authors:  F Brugnone; L Perbellini; L Grigolini; P Apostoli
Journal:  Int Arch Occup Environ Health       Date:  1978-09-15       Impact factor: 3.015

6.  Advances in breath hydrogen quantitation in paediatrics: sample collection and normalization to constant oxygen and nitrogen levels.

Authors:  T A Robb; G P Davidson
Journal:  Clin Chim Acta       Date:  1981-04-09       Impact factor: 3.786

7.  Lung uptake and metabolism of cyclohexane in shoe factory workers.

Authors:  L Perbellini; F Brugnone
Journal:  Int Arch Occup Environ Health       Date:  1980       Impact factor: 3.015

8.  Cold urticaria: release into the circulation of histamine and eosinophil chemotactic factor of anaphylaxis during cold challenge.

Authors:  N A Soter; S I Wasserman; K F Austen
Journal:  N Engl J Med       Date:  1976-03-25       Impact factor: 91.245

9.  Studies in breath-alcohol analysis: biological factors.

Authors:  K M Dubowski
Journal:  Z Rechtsmed       Date:  1975-11-11

10.  Improved gas chromatographic quantitation of breath hydrogen by normalization to respiratory carbon dioxide.

Authors:  H C Niu; D A Schoeller; P D Klein
Journal:  J Lab Clin Med       Date:  1979-11
View more
  2 in total

1.  Human exposure to styrene. VI. Percutaneous absorption in human volunteers.

Authors:  M Berode; P O Droz; M Guillemin
Journal:  Int Arch Occup Environ Health       Date:  1985       Impact factor: 3.015

2.  Alveolar sampling and fast kinetics of tetrachloroethene in man. I. Alveolar sampling.

Authors:  J J Opdam; J F Smolders
Journal:  Br J Ind Med       Date:  1986-12