Literature DB >> 6801246

Skin surface PCO2 monitoring in newborn infants in shock: effect of hypotension and electrode temperature.

I Brünstler, A Enders, H T Versmold.   

Abstract

We studied the effect of hypotension and of electrode temperature (41 degrees C to 44 degrees C) on the relation of skin surface PCO2 (Roche prototype) to arterial PCO2 in 24 sick neonates of 690 to 3,500 gm with systolic blood pressures of 5 to 70 mm Hg. PsCO2 closely correlated with PaCO2. The standard error of estimating PaCO2 from PsCO2 was 3.02 torr at 44 degrees C, 3.20 torr at 43 degrees C, and 3.57 torr at 41 degrees C. The pH (6.89 to 7.61), body temperature (33.5 to 38.1 degrees C), hematocrit (0.28 to 0.65), scleredema, or treatment with tolazoline did not affect the relation of PsCO2 to PaCO2. PsCO2 grossly exceeded the predicted value at systolic blood pressures below 15 mm Hg, irrespective of electrode temperature.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 6801246     DOI: 10.1016/s0022-3476(82)80459-9

Source DB:  PubMed          Journal:  J Pediatr        ISSN: 0022-3476            Impact factor:   4.406


  6 in total

Review 1.  Non-invasive monitoring of carbon-dioxide in newborns and children.

Authors:  S Dutta
Journal:  Indian J Pediatr       Date:  1999 Jan-Feb       Impact factor: 1.967

Review 2.  Transcutaneous carbon dioxide monitoring.

Authors:  J M Rennie
Journal:  Arch Dis Child       Date:  1990-04       Impact factor: 3.791

3.  Continuous neonatal blood gas monitoring using a multiparameter intra-arterial sensor.

Authors:  C Morgan; S J Newell; D A Ducker; J Hodgkinson; D K White; C J Morley; J M Church
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1999-03       Impact factor: 5.747

4.  Characteristics of transcutaneous carbon dioxide tension monitors in normal adults and critically ill patients.

Authors:  S V Rithalia; T H Clutton-Brock; J Tinker
Journal:  Intensive Care Med       Date:  1984       Impact factor: 17.440

5.  Effects of the transcutaneous electrode temperature on the accuracy of transcutaneous carbon dioxide tension.

Authors:  Line C Sørensen; Lene Brage-Andersen; Gorm Greisen
Journal:  Scand J Clin Lab Invest       Date:  2011-07-06       Impact factor: 1.713

6.  Validation of a new combined transcutaneous tcPCO2 and tcPO2 sensor in children in the operating theater.

Authors:  Jan J van Wijk; Willem van Weteringen; Sanne E Hoeks; Lonneke M Staals
Journal:  Paediatr Anaesth       Date:  2021-12-15       Impact factor: 2.129

  6 in total