Literature DB >> 6800700

The effects of a fluctuating Fio2 on metabolic measurements in mechanically ventilated patients.

J A Browning, S E Linberg, S Z Turney, P Chodoff.   

Abstract

The determination of minute oxygen consumption (VO2) for metabolic studies on patients using either the Beckman Metabolic Cart (MMC) or the Respiratory Monitoring System (RMS) requires a stable fractional inspired oxygen concentration (FIO2). Measurement of VO2 on mechanically ventilated patients using the Bourns BEAR 1 and the Engstrom 311 and 312 was unsuccessful due to FIO2 variations greater than the acceptable limits. The inspiratory and expiratory O2 and CO2 waveforms were studied using various methods of supplying source gas to the ventilators. A method using an external air/oxygen blender was found that provided a stable FIO2 for metabolic measurements for each of the ventilators tested.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 6800700     DOI: 10.1097/00003246-198202000-00003

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  9 in total

1.  Sequential changes in the metabolic response in critically injured patients during the first 25 days after blunt trauma.

Authors:  D N Monk; L D Plank; G Franch-Arcas; P J Finn; S J Streat; G L Hill
Journal:  Ann Surg       Date:  1996-04       Impact factor: 12.969

2.  Validation of a new closed circuit indirect calorimetry method compared with the open Douglas bag method.

Authors:  J M Raurich; J Ibañez; P Marse
Journal:  Intensive Care Med       Date:  1989       Impact factor: 17.440

Review 3.  Nutritional support in the management of critically ill patients in surgical intensive care.

Authors:  S J Streat; G L Hill
Journal:  World J Surg       Date:  1987-04       Impact factor: 3.352

4.  Design and validation of an automatic metabolic monitor.

Authors:  B W Feenstra; W P Holland; J J van Lanschot; H A Bruining
Journal:  Intensive Care Med       Date:  1985       Impact factor: 17.440

5.  Artifacts in the assessment of metabolic gas exchange.

Authors:  B W Feenstra; J J van Lanschot; C G Vermeij; H A Bruining
Journal:  Intensive Care Med       Date:  1986       Impact factor: 17.440

6.  Oxygen consumption after cardiac surgery--a comparison between calculation by Fick's principle and measurement by indirect calorimetry.

Authors:  P Bizouarn; D Soulard; Y Blanloeil; A Guillet; Y Goarin
Journal:  Intensive Care Med       Date:  1992       Impact factor: 17.440

7.  Clinical validation of the Deltatrac monitoring system in mechanically ventilated patients.

Authors:  S Tissot; B Delafosse; O Bertrand; Y Bouffard; J P Viale; G Annat
Journal:  Intensive Care Med       Date:  1995-02       Impact factor: 17.440

8.  Comparison of respiratory quotient and resting energy expenditure in two regimens of enteral feeding - continuous vs. intermittent in head-injured critically ill patients.

Authors:  Indubala Maurya; Mridula Pawar; Rakesh Garg; Mohandeep Kaur; Rajesh Sood
Journal:  Saudi J Anaesth       Date:  2011-04

Review 9.  Indirect Calorimetry: History, Technology, and Application.

Authors:  Haifa Mtaweh; Lori Tuira; Alejandro A Floh; Christopher S Parshuram
Journal:  Front Pediatr       Date:  2018-09-19       Impact factor: 3.418

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.