Literature DB >> 6789645

Contrast enhancement in abdominal CT: bolus vs. infusion.

F A Burgener, D J Hamlin.   

Abstract

The accuracy of in vivo iodine estimations by CT in the aortic blood was determined in the dog. Iodine wash-out curves of five patients each receiving either a bolus of 100 ml diatrizoate 60% or a 10 min infusion of 300 ml diatrizoate 30% and 138 nonenhanced abdominal CT scans with various lesions in 104 patients were analyzed. This investigation suggests: (1) In vivo estimations of iodine concentrations are subject to considerable variation. (2) Iodine accumulation and wash-out for a given contrast administration mode are similar in liver, spleen, and pancreas with tissue iodine concentrations always below blood iodine concentrations, while a significant iodine concentration above iodine blood levels is found in the renal parenchyma. (3) If contrast enhancement is analyzed separately for bolus effect (arteriovenous iodine difference [AVID] greater than 30 H), nonequilibrium phase (AVID 10-30 H) and equilibrium phase (AVID less than 10 H), a good correlation between aortic blood and tissue iodine concentration is found for the latter two phases in the kidney, liver, and spleen which is independent of the contrast administration mode. (4) Visualization of all focal (cystic and solid) lesions is improved in the kidneys after contrast enhancement, while in the other investigated abdominal organs only cystic lesions are always better visualized on the enhanced scan regardless of contrast material dose, administration mode, and time of scanning. (5) Improved visualization of a solid lesion in liver, spleen, and pancreas is most likely achieved by scanning during bolus effect and the nonequilibrium phase, that is, within the first 2 min after a contrast material bolus or during a contrast material infusion. The chance to conceal a lesion in these organs increases significantly when performed at a later stage after contrast administration, that is, in the equilibrium phase.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 6789645     DOI: 10.2214/ajr.137.2.351

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  5 in total

1.  Focal hepatic lesions: detection by dynamic and delayed computed tomography versus short TE/TR spin echo and fast field echo magnetic resonance imaging.

Authors:  R C Nelson; J L Chezmar; H V Steinberg; W E Torres; B R Baumgartner; R K Gedgaudas-McClees; M E Bernardino
Journal:  Gastrointest Radiol       Date:  1988

2.  Hepatic spiral CT in children: scan delay time-enhancement analysis.

Authors:  G D Luker; M J Siegel; D A Bradley; J D Baty
Journal:  Pediatr Radiol       Date:  1996

3.  Cluster scanning in body CT.

Authors:  P M Silverman; R J Wechsler; D Griego; C Cooper; W J Davros; R K Zeman
Journal:  Abdom Imaging       Date:  1994 May-Jun

Review 4.  An overview of the clinical pharmacokinetics of x-ray contrast media.

Authors:  M Bourin; P Jolliet; F Ballereau
Journal:  Clin Pharmacokinet       Date:  1997-03       Impact factor: 6.447

5.  Computed tomography in the detection of small hepatocellular carcinomas.

Authors:  K Inamoto; S Tanaka; H Yamazaki; E Okamoto
Journal:  Gastrointest Radiol       Date:  1983
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.