Measurement of stroke volume with impedance cardiography.

I Milsom, R Sivertsson, B Biber, T Olsson.   

Abstract

Simultaneous determination of stroke volume with impedance cardiography and the dye dilution technique was compared in 11 healthy men before and after exercise. The correlation coefficient for all measurements was 0.82. Mean stroke volume determined by impedance cardiography was significantly (P less than 0.001) lower than mean stroke volume calculated by the dye dilution technique. However, there was no significant difference in the mean change in stroke volume determined by the two techniques during serial measurements. The reproducibility of single impedance-determined stroke volumes (6.9 ml) was not significantly different from single values obtained by dye dilution (7.3 ml). Impedance cardiography was found to be a safe, reliable, non-invasive method for the measurement of changes in stroke volume in healthy individuals before and after exercise. At present, direct estimation of absolute values of stroke volume is not recommended using impedance cardiography. Calibration of the impedance technique against other established techniques in a given application is necessary.

Entities:  

Mesh:

Year:  1982        PMID: 6754214     DOI: 10.1111/j.1475-097x.1982.tb00047.x

Source DB:  PubMed          Journal:  Clin Physiol        ISSN: 0144-5979


  10 in total

1.  The cardiovascular effects of oral nifedipine and nicardipine: a double-blind comparison in healthy volunteers using transthoracic bioimpedance cardiography.

Authors:  S H Thomas; P Molyneux; J Kelly; S E Smith
Journal:  Eur J Clin Pharmacol       Date:  1990       Impact factor: 2.953

2.  Influence of age on the immediate cardiovascular response to orthostatic manoeuvre.

Authors:  G Cybulski
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1996

3.  Cardiovascular and sympatho-adrenal responses to static handgrip performed with one and two hands.

Authors:  R Grucza; J F Kahn; G Cybulski; W Niewiadomski; E Stupnicka; K Nazar
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1989

4.  Proceedings of the British Pharmacological Society, Clinical Pharmacology Section. 5-7 April 1989, Bristol. Abstracts.

Authors: 
Journal:  Br J Clin Pharmacol       Date:  1989-08       Impact factor: 4.335

5.  Stroke volume and systolic time intervals: beat-to-beat comparison between echocardiography and ambulatory impedance cardiography in supine and tilted positions.

Authors:  G Cybulski; E Michalak; E Koźluk; A Piatkowska; W Niewiadomski
Journal:  Med Biol Eng Comput       Date:  2004-09       Impact factor: 2.602

6.  Non-invasive measurement of cardiac output: whole-body impedance cardiography in simultaneous comparison with thermodilution and direct oxygen Fick methods.

Authors:  T Kööbi; S Kaukinen; T Ahola; V M Turjanmaa
Journal:  Intensive Care Med       Date:  1997-11       Impact factor: 17.440

7.  Portal blood flow in man during graded positive end-expiratory pressure ventilation.

Authors:  O Winsö; B Biber; B Gustavsson; C Holm; I Milsom; D Niemand
Journal:  Intensive Care Med       Date:  1986       Impact factor: 17.440

8.  Stroke volume measurement during supine and upright cycle exercise by impedance cardiography.

Authors:  J K Moon; A R Coggan; M K Hopper; L E Baker; E F Coyle
Journal:  Ann Biomed Eng       Date:  1994 Sep-Oct       Impact factor: 3.934

9.  Haemodynamic effects and kinetics of concomitant intravenous disopyramide and atenolol in patients with ischaemic heart disease.

Authors:  J Bonde; L E Pedersen; H R Angelo; J Trap-Jensen; T L Svendsen; J P Kampmann
Journal:  Eur J Clin Pharmacol       Date:  1986       Impact factor: 2.953

10.  Design and Implementation of a Portable Impedance Cardiography System for Noninvasive Stroke Volume Monitoring.

Authors:  Hassan Yazdanian; Amin Mahnam; Mehdi Edrisi; Morteza Abdar Esfahani
Journal:  J Med Signals Sens       Date:  2016 Jan-Mar