Literature DB >> 6751233

Evaluation of factors affecting the membrane filter technique for testing drinking water.

S C Hsu, T J Williams.   

Abstract

The following studies were done in response to questions regarding the adoption and use of the membrane filter (MF) technique for testing drinking water for the total coliform indicator group. A comparison with the most-probable-number technique showed that MF procedures with m-Endo agar LES were somewhat superior to the most-probable-number methods in terms of numbers of coliform organims recovered. Medium preparation and storage studies indicated that rehydration of m-Endo agar LES should be done with boiling water for less than 15 min, that m-Endo agar LES should not be exposed to light for more than 4 to 6 h, and that m-Endo agar LES plates may be used for up to 4 weeks and broth verification media for up to 3 weeks under given storage conditions. MF culture colonies were commonly found which did not produce sheen as expected for coliforms and yet were verified as coliforms. The occurrence and morphology of these atypical colonies were studied. Parallel inoculation of both lauryl tryptose (LT) and brilliant green bile (BGB) broth was found to be a better colony verification approach than recommended LT preenrichment before transfer to BGB. Comparison of parallel verification results indicated very little justification for the use of LT medium in MF verification procedures. In the case of overgrown or confluent cultures, the best coliform recoveries resulted from swabbing the MF plate and directly inoculating BGB medium with the swab. The occurrence of overgrowth was defined and evidence was collected suggesting that overgrowth is a function of sample holding time. Evaluation of routine test data and bacterial population reductions as a function of time indicated that nonquantitative recovery of coliforms may not be significantly affected for at least a 72-h sample holding time.

Entities:  

Mesh:

Year:  1982        PMID: 6751233      PMCID: PMC242031          DOI: 10.1128/aem.44.2.453-460.1982

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  2 in total

1.  Evaluation of the reliability of coliform density tests.

Authors:  J A McCARTHY; H A THOMAS; J E DELANEY
Journal:  Am J Public Health Nations Health       Date:  1958-12

2.  Impact of verification media and resuscitation on accuracy of the membrane filter total coliform enumeration technique.

Authors:  T M Evans; R J Seidler; M W LeChevallier
Journal:  Appl Environ Microbiol       Date:  1981-05       Impact factor: 4.792

  2 in total
  5 in total

1.  Anaerobic incubation of membrane filter cultures for improved detection of fecal coliforms from recreational waters.

Authors:  J D Doyle; B Tunnicliff; S K Brickler; R E Kramer; N A Sinclair
Journal:  Appl Environ Microbiol       Date:  1984-08       Impact factor: 4.792

2.  Detection of false-positives among total and fecal coliform counts by factorial analysis of correspondence.

Authors:  M Joncas; S Michaud; J P Carmichael; M C Lavoie
Journal:  Appl Environ Microbiol       Date:  1985-01       Impact factor: 4.792

3.  Effect of noncoliforms on coliform detection in potable groundwater: improved recovery with an anaerobic membrane filter technique.

Authors:  S G Franzblau; B J Hinnebusch; L M Kelley; N A Sinclair
Journal:  Appl Environ Microbiol       Date:  1984-07       Impact factor: 4.792

4.  Holding effects on coliform enumeration in drinking water samples.

Authors:  A E McDaniels; R H Bordner; P S Gartside; J R Haines; K P Brenner; C C Rankin
Journal:  Appl Environ Microbiol       Date:  1985-10       Impact factor: 4.792

5.  Bacterial interference with coliform colony sheen production on membrane filters.

Authors:  G A Burlingame; J McElhaney; M Bennett; W O Pipes
Journal:  Appl Environ Microbiol       Date:  1984-01       Impact factor: 4.792

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.