Literature DB >> 6724663

Evaluation of the Remler M2000 blood pressure recorder. Comparison with intraarterial blood pressure recordings both at hospital and at home.

B A Gould, R S Hornung, H A Kieso, D G Altman, P M Cashman, E B Raftery.   

Abstract

The Remler M2000 is a semiautomated device that has been used to collect epidemiological data and assess blood pressure variability. It has been subjected to limited evaluation in operation, however, and no studies of its accuracy away from the hospital or office environment have been undertaken. We recruited a group of 28 patients with essential hypertension who were undergoing intraarterial ambulatory blood pressure monitoring and compared the intraarterial recordings with those made with the Remler instrument both at home and in the hospital. The Remler recordings were also compared with simultaneous indirect blood pressure measurements made with the random zero sphygmomanometer. The mean difference between the Remler and intraarterial blood pressure recordings was -3/7 in the hospital and 7/0 at home. All standard deviations were greater than 10 mm Hg, indicating large between-subject variability. Overall, the relationship of the Remler M2000 readings to intraarterial pressures was as close if not closer than standard indirect sphygmomanometry and thus might provide useful data for epidemiological surveys or drug trials. It would appear that for accurate measurement of short-term blood pressure variation and 24-hour recording, intraarterial recording is the method of choice.

Entities:  

Mesh:

Year:  1984        PMID: 6724663

Source DB:  PubMed          Journal:  Hypertension        ISSN: 0194-911X            Impact factor:   10.190


  5 in total

1.  Effects of prolonged administration of the angiotensin converting enzyme inhibitor CGS 16617 in normotensive volunteers.

Authors:  G Waeber; M Burnier; M Porchet; J Nussberger; B Waeber; H R Brunner
Journal:  Eur J Clin Pharmacol       Date:  1989       Impact factor: 2.953

2.  A Meta-analysis to Determine the Validity of Taking Blood Pressure Using the Indirect Cuff Method.

Authors:  Scott J Dankel; Minsoo Kang; Takashi Abe; Jeremy P Loenneke
Journal:  Curr Hypertens Rep       Date:  2019-02-07       Impact factor: 5.369

3.  Ambulatory pressure monitoring in the assessment of antihypertensive therapy.

Authors:  A J Coats; J Conway; V K Somers; J E Isea; P Sleight
Journal:  Cardiovasc Drugs Ther       Date:  1989-06       Impact factor: 3.727

4.  Nadolol in essential hypertension: effect on ambulatory blood pressure, renal haemodynamics and cardiac function.

Authors:  A G Dupont; P Vanderniepen; A M Bossuyt; M H Jonckheer; R O Six
Journal:  Br J Clin Pharmacol       Date:  1985-08       Impact factor: 4.335

5.  Double-blind, randomized comparative study of the antihypertensive effect of nicardipine slow-release and nifedipine slow-release in hypertensive patients with coronary heart disease.

Authors:  F K Maetzel; W E Teufel; A Griebel; M H Glocke
Journal:  Cardiovasc Drugs Ther       Date:  1991-06       Impact factor: 3.727

  5 in total