[Dimensional changes of polyethylene acetabuli in Müller's hip endoprosthesis. Report on measurement methods and their clinical significance].

U Buchhorn, H G Willert, M Semlitsch, H Weber.   

Abstract

The dimensional changes of hip sockets of total endoprosthesis of the Müller Type are subject of this article. Regular-anterior/posterior radiographs of the pelvis were taken to determine the orientation of the center of the prosthetic head in relation to the wire marker of the poly(ethylene) cup. Further measurements were done using casts of worn acetabular cups gained at revisional surgery. The possible errors of measurements of both methods are discussed. Both, creep and wear contribute to the dimensional changes of the hip sockets, the proportional amount of each mechanism is not known. Data from laboratory examinations suggest a relatively high rate of creep in the early time of function. With longer periods the dimensional changes are predominantly caused by wear. In the beginning of joint function our measurements show a high rate of the yearly dimensional change. The shift of the head amounted 0.5 mm per year and diminished after five years to rates of 0.15 to 0.2 mm. All dimensional changes that exceed a shift to the head of 0.2 mm per year are considered to be unfavourable and to contribute to loosening.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6720034     DOI: 10.1055/s-2008-1044596

Source DB:  PubMed          Journal:  Z Orthop Ihre Grenzgeb        ISSN: 0044-3220


  4 in total

1.  Uncoated polyethylene RM acetabular component versus Müller cemented acetabular component. A 4- to 8-year follow-up study.

Authors:  M Krismer; M Fischer; T Klestil; B Frischhut
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

2.  Osteolysis, wear and failure of a migrating acetabular component. A roentgen stereophotogram case report.

Authors:  I Onsten; B Mjöberg
Journal:  Arch Orthop Trauma Surg       Date:  1995       Impact factor: 3.067

3.  Osteolysis around uncoated polyethylene acetabular cups : A seven- to nine-year follow-up of 79 hips.

Authors:  T J Niinimäki; M M Ruuskanen; P K Jalovaara
Journal:  Eur J Orthop Surg Traumatol       Date:  1995-12

4.  Polyethylene wear in total hip prostheses: the influence of direction of linear wear on volumetric wear determined from radiographic data.

Authors:  R Kosak; V Antolic; V Pavlovcic; V Kralj-Iglic; I Milosev; G Vidmar; A Iglic
Journal:  Skeletal Radiol       Date:  2003-09-13       Impact factor: 2.199

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.