Literature DB >> 6715698

Effects of intraaortic balloon counterpulsation on myocardial blood flow in patients with severe coronary artery disease.

S C Port, S Patel, D H Schmidt.   

Abstract

The purpose of this study was to test the hypothesis that myocardial blood flow distal to a critical stenosis would increase during intraaortic balloon counterpulsation. Accordingly, 13 patients with severe coronary artery disease were studied at the time of elective preoperative insertion of an intraaortic balloon catheter. Hemodynamic measurements and measurements of myocardial blood flow were made before and during counterpulsation. Myocardial blood flow was measured with a xenon-133 washout technique. Compared with control measurements, the heart rate decreased from 87.8 +/- 18.8 to 82.8 +/- 13.4 beats/min (p = 0.02) and systolic arterial pressure decreased from 112.1 +/- 17.9 to 97.8 +/- 14.8 mm Hg (p = 0.004) during counterpulsation. Diastolic arterial pressure increased from 72.2 +/- 10.1 to 120.2 +/- 21.4 mm Hg (p = 0.00002) during counterpulsation. Myocardial blood flow for the entire group decreased from 48.8 +/- 14.1 to 42.6 +/- 11.0 ml/100 g per min (p = 0.008). Regional flows in the left anterior descending and circumflex distributions also decreased. Left anterior descending artery blood flow decreased insignificantly from 51.5 +/- 14.4 to 47.4 +/- 11.7 ml/100 g per min (p = not significant), while circumflex flow decreased from 50.7 +/- 12.2 to 41.1 +/- 8.9 ml/100 g per min (p = 0.008). When normalized for the rate-pressure product, myocardial blood flow was 53 +/- 16 X 10(-4) at rest and 55 +/- 12 X 10(-4) (p = not significant) during counterpulsation.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1984        PMID: 6715698     DOI: 10.1016/s0735-1097(84)80273-9

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  6 in total

1.  Computational analysis of the effect of the type of LVAD flow on coronary perfusion and ventricular afterload.

Authors:  Ki Moo Lim; In Su Kim; Seong Wook Choi; Byung Goo Min; Yong Soon Won; Heon Young Kim; Eun Bo Shim
Journal:  J Physiol Sci       Date:  2009-04-23       Impact factor: 2.781

Review 2.  How New Support Devices Change Critical Care Delivery.

Authors:  Asma Zainab; Divina Tuazon; Faisal Uddin; Iqbal Ratnani
Journal:  Methodist Debakey Cardiovasc J       Date:  2018 Apr-Jun

Review 3.  Evidence of clinical efficacy of counterpulsation therapy methods.

Authors:  M Capoccia; C T Bowles; J R Pepper; N R Banner; A R Simon
Journal:  Heart Fail Rev       Date:  2015-05       Impact factor: 4.214

Review 4.  Mechanical Circulatory Assist Devices: Available Modalities and Review of Literature.

Authors:  Mohammed Faluk; Syed Mustajab Hasan; Tianyu Jiang; Ramy Abdelmaseih; Jigar Patel
Journal:  Heart Views       Date:  2021-01-14

5.  Intra-aortic Balloon Counterpulsation for High-Risk Percutaneous Coronary Intervention: Defining Coronary Responders.

Authors:  Natalia Briceno; Kalpa De Silva; Matthew Ryan; Tiffany Patterson; Kevin O'Gallagher; Howard Ellis; Simone Rivolo; Jack Lee; Simon Redwood; Ajay M Shah; Michael Marber; Divaka Perera
Journal:  J Cardiovasc Transl Res       Date:  2019-03-15       Impact factor: 4.132

6.  Intra-aortic balloon pump in patients with cardiogenic shock complicating myocardial infarction: a systematic review and meta-analysis of randomized trials (protocol).

Authors:  Sultan Altayyar; Bram Rochwerg; Sami Alnasser; Awad Al-Omari; Bandar Baw; Alison Fox-Robichaud; Waleed Alhazzani
Journal:  Syst Rev       Date:  2014-03-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.