In-phase rejection requirements for measuring respiratory input impedance.

R Peslin, P Jardin, C Duvivier, P Begin.   

Abstract

Respiratory flow is commonly obtained by measuring the pressure difference across a pneumotachograph. When respiratory input impedance is studied, that pressure difference may be very small with respect to the absolute pressure swings inside the pneumotachograph. Then the in-phase rejection of the differential pressure transducer is expected to markedly influence the accuracy of the data. The problem was investigated by computer simulation and by measurements on a mechanical analog of the respiratory system made of a resistance, an inertance, and a compliance arranged in series. Both studies demonstrated that comparatively small differences in the volumes of the chambers or in the lengths or diameters of the connecting tubes led to artifactual frequency dependence of resistance and serious misestimation of compliance and inertance. Errors were larger when the resistance of the pneumotachograph was smaller and the impedance of the subject larger. In practice, with usual pneumotachographs accurate impedance measurements require using the most symmetrical transducers presently available (common-mode rejection ratio of about 70 dB at 30 Hz).

Mesh:

Year:  1984        PMID: 6706784     DOI: 10.1152/jappl.1984.56.3.804

Source DB:  PubMed          Journal:  J Appl Physiol Respir Environ Exerc Physiol        ISSN: 0161-7567


  7 in total

1.  Mechanical impedance of the canine diaphragm. Part 1. Experimental system and measurements.

Authors:  B Suki; B Daróczy; Z Hantos
Journal:  Med Biol Eng Comput       Date:  1990-07       Impact factor: 2.602

2.  Analysis of the dynamic characteristics of pressure transducers for studying respiratory mechanics at high frequencies.

Authors:  R Farré; R Peslin; D Navajas; C Gallina; B Suki
Journal:  Med Biol Eng Comput       Date:  1989-09       Impact factor: 2.602

3.  Linear servo-controlled pressure generator for forced oscillation measurements.

Authors:  P L de Melo; M M Werneck; A Giannella-Neto
Journal:  Med Biol Eng Comput       Date:  1998-01       Impact factor: 2.602

4.  Lumped parameter approximation for the prediction of the dynamic response of the Fleisch pneumotachograph.

Authors:  M J Turner; I M MacLeod; A D Rothberg
Journal:  Med Biol Eng Comput       Date:  1988-07       Impact factor: 2.602

5.  Design and nonlinear modeling of a sensitive sensor for the measurement of flow in mice.

Authors:  Samer Bou Jawde; Bradford J Smith; Adam Sonnenberg; Jason H T Bates; Béla Suki
Journal:  Physiol Meas       Date:  2018-07-03       Impact factor: 2.833

6.  Two-point calibration procedure of the forced oscillation technique.

Authors:  K N Desager; M Cauberghs; K P Van de Woestijne
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

7.  Forced oscillation assessment of respiratory mechanics in ventilated patients.

Authors:  D Navajas; R Farré
Journal:  Crit Care       Date:  2000-12-20       Impact factor: 9.097

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.