Literature DB >> 6689922

Doppler echocardiography in the study of patients with mitral disc valve prostheses.

S Nitter-Hauge.   

Abstract

A combination of M mode and Doppler echocardiography was used to study patients with mitral disc valve prostheses. The probe used in these investigations consisted of a circular Doppler crystal mounted around the M mode crystal in the same plane. Because of the strong echoes produced by the prosthesis the transducer (probe) could be angled for optimum Doppler signals without losing the M mode echocardiographic recording of the prosthesis. With this equipment mean and maximum blood velocities and Doppler amplitude signals could be measured simultaneously with M mode echocardiography. A depth indication line in the M mode recording ensured that the Doppler signal was recorded in the region of interest. The Doppler ultrasound technique was also used separately in both the pulsed wave and the continuous wave mode. The data show the usefulness of this technique in patients with normally functioning valve prostheses and in three patients with valve malfunction due to thrombus formation. The data in the latter three cases seem to indicate that the Doppler technique provides valuable information in addition to that obtained by M mode echocardiography in recognising mitral valve prosthetic malfunction.

Entities:  

Mesh:

Year:  1984        PMID: 6689922      PMCID: PMC482315          DOI: 10.1136/hrt.51.1.61

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  13 in total

1.  Malfunction of a Bjork-Shiley prosthetic heart valve in the mitral position producing an abnormal echocardiographic pattern.

Authors:  S D Clements; J V Perkins
Journal:  J Clin Ultrasound       Date:  1978-10       Impact factor: 0.910

2.  Delayed opening of Beall mitral prosthetic valve detected by echocardiography.

Authors:  N Kawai; B L Segal; J W Linhart
Journal:  Chest       Date:  1975-02       Impact factor: 9.410

3.  Echocardiographic determination of mitral disc valve excursion.

Authors:  M L Johnson; J H Holmes; B C Paton
Journal:  Circulation       Date:  1973-06       Impact factor: 29.690

4.  Dysfunction of the Beall mitral prosthesis and its detection by cinefluoroscopy and echocardiography.

Authors:  P B Oliva; M L Johnson; M Pomerantz; A Levene
Journal:  Am J Cardiol       Date:  1973-03       Impact factor: 2.778

5.  Diagnosis of valvular heart disease using transcutaneous Doppler ultrasound.

Authors:  A O Brubakk; B A Angelsen; L Hatle
Journal:  Cardiovasc Res       Date:  1977-09       Impact factor: 10.787

6.  Clinical and haemodynamic results following mitral valve replacement with the new Lillehei-Kaster pivoting disc valve prosthesis.

Authors:  S Nitter-Hauge; T Froysaker; K V Hall
Journal:  Scand J Thorac Cardiovasc Surg       Date:  1977

7.  An ultrasound Doppler technique for the noninvasive determination of the pressure gradient in the Björk-Shiley mitral valve.

Authors:  J Holen; S Simonsen; T Frøysaker
Journal:  Circulation       Date:  1979-03       Impact factor: 29.690

8.  Thrombosed Björk-Shiley mitral prostheses.

Authors:  H Copans; J B Lakier; R H Kinsley; P R Colsen; V U Fritz; J B Barlow
Journal:  Circulation       Date:  1980-01       Impact factor: 29.690

9.  Malfunction of mitral ball valve prosthesis due to thrombus. Report of 2 cases with notes on early clinical diagnosis.

Authors:  J Pfeifer; N Godlschlager; T Sweatman; F Gerbode; A Selzer
Journal:  Am J Cardiol       Date:  1972-01       Impact factor: 2.778

10.  Malfunction of Björk-Shiley valve prosthesis in tricuspid position.

Authors:  P D Bourdillon; G P Sharratt
Journal:  Br Heart J       Date:  1976-11
View more
  2 in total

1.  Valvar prosthetic dysfunction. Localisation and evaluation of the dysfunction using the Doppler technique.

Authors:  C Veyrat; S Witchitz; A Lessana; A Ameur; G Abitbol; D Kalmanson
Journal:  Br Heart J       Date:  1985-09

2.  Auscultatory characteristics of normally functioning Lillehei-Kaster, Björk-Shiley, and St Jude heart valve prostheses.

Authors:  M Kupari; A Harjula; S Mattila
Journal:  Br Heart J       Date:  1986-04