Auscultatory characteristics of normally functioning Lillehei-Kaster, Björk-Shiley, and St Jude heart valve prostheses.

M Kupari, A Harjula, S Mattila.   

Abstract

Auscultatory and echocardiographic and phonocardiographic studies were performed on 26 patients who had a total of 11 Lillehei-Kaster, 16 Björk-Shiley, and 18 St Jude heart valve prostheses functioning normally in the aortic or mitral positions or both. With all types and positions of prostheses a distinct closing sound was always detected. It was frequently heard in two parts which, according to echocardiographic and phonocardiographic studies, resulted from the onset and completion of the valve closure. An opening sound could be heard from all Björk-Shiley and St Jude valves but from only four of the 11 Lillehei-Kaster valves. The opening sounds due to mitral prostheses consisted of two to three closely spaced clicks detected as a faint early diastolic crackle on auscultation. Echocardiography with phonocardiography indicated that they were related to the onset and termination of the disc opening excursion. In the aortic position the valves always produced early to mid-systolic murmurs, and a soft early diastolic murmur was also heard in seven of 23 patients. A mid-diastolic rumble was heard in 12 of 22 patients with mitral prostheses. Normally functioning tilting disc valve prostheses produce characteristic auscultatory findings, and familiarity with these findings will be useful in clinical evaluation of patients with these prostheses.

Entities:  

Mesh:

Year:  1986        PMID: 3964503      PMCID: PMC1236739          DOI: 10.1136/hrt.55.4.364

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  18 in total

1.  Echo- and phonocardiographic studies in patients with Lillehei-Kaster aortic valve prostheses.

Authors:  S Vardan; R Warner; S Mookherjee; M Mead; A I Obeid
Journal:  Jpn Heart J       Date:  1979-05

2.  Thrombosis on Bjork-Shiley aortic valve prosthesis. Clinical, arteriographic, echocardiographic and therapeutic observations in seven cases.

Authors:  J Ben-Zvi; F J Hildner; P A Chandraratna; P Samet
Journal:  Am J Cardiol       Date:  1974-10-03       Impact factor: 2.778

3.  Auscultatory and phonocardiographic findings in patients with prosthetic ball-valves.

Authors:  M Najmi; B L Segal
Journal:  Am J Cardiol       Date:  1965-12       Impact factor: 2.778

4.  Doppler echocardiography in the study of patients with mitral disc valve prostheses.

Authors:  S Nitter-Hauge
Journal:  Br Heart J       Date:  1984-01

5.  Thrombosed Björk-Shiley mitral prostheses.

Authors:  H Copans; J B Lakier; R H Kinsley; P R Colsen; V U Fritz; J B Barlow
Journal:  Circulation       Date:  1980-01       Impact factor: 29.690

6.  Echophonocardiographic findings in patients with prosthetic heart valve malfunction.

Authors:  C L Cunha; E R Giuliani; J A Callahan; J R Pluth
Journal:  Mayo Clin Proc       Date:  1980-04       Impact factor: 7.616

7.  Thrombosis of St. Jude medical cardiac valve in the mitral position.

Authors:  P J Commerford; E A Lloyd; J A De Nobrega
Journal:  Chest       Date:  1981-09       Impact factor: 9.410

8.  Echocardiographic features of the correctly functioning St. Jude Medical valve prosthesis.

Authors:  F W Amann; D Burckhardt; J Hasse; E Grädel
Journal:  Am Heart J       Date:  1981-01       Impact factor: 4.749

9.  Echocardiographic and phonocardiographic assessment of the St. Jude cardiac valve prosthesis.

Authors:  N L DePace; M N Kotler; G S Mintz; R Lichtenberg; I P Goel; B L Segal
Journal:  Chest       Date:  1981-09       Impact factor: 9.410

10.  Fibrinolytic treatment of thrombus on prosthetic heart valves.

Authors:  S Witchitz; C Veyrat; P Moisson; N Scheinman; L Rozenstajn
Journal:  Br Heart J       Date:  1980-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.