Literature DB >> 6686326

Comparison of propranolol and propranolol LA in hypertension using 24-hr noninvasive blood pressure monitoring.

M H Rustin, E N Coomes.   

Abstract

The technique of non-invasive blood pressure monitoring was used to compare the 24-hr control of blood pressure in 10 patients with essential hypertension taking either twice daily propranolol or a once daily long-acting formulation of propranolol (propranolol LA). Both drug regimes produced smooth control of blood pressure and heart rate through the 24 hours and significantly reduced blood pressure and heart rate on bicycle ergometry tests. There was no significant difference between the two treatments. The non-invasive oscillometric method of measuring 24-hr control of blood pressure provides an alternative to ambulatory intra-arterial monitoring.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6686326      PMCID: PMC2417800          DOI: 10.1136/pgmj.59.698.770

Source DB:  PubMed          Journal:  Postgrad Med J        ISSN: 0032-5473            Impact factor:   2.401


  12 in total

1.  Median nerve palsy--a complication of brachial artery cannulation.

Authors:  W A Littler
Journal:  Postgrad Med J       Date:  1976       Impact factor: 2.401

Review 2.  ABC of blood pressure measurement. Reconciling the controversies: a comment on "the literature".

Authors:  E T O'Brien; K O'Malley
Journal:  Br Med J       Date:  1979-11-10

3.  Noninvasive automatic determination of mean arterial pressure.

Authors:  M Ramsey
Journal:  Med Biol Eng Comput       Date:  1979-01       Impact factor: 2.602

4.  Pharmacokinetic and pharmacodynamic studies with long-acting propranolol.

Authors:  J McAinsh; N S Baber; R Smith; J Young
Journal:  Br J Clin Pharmacol       Date:  1978-08       Impact factor: 4.335

5.  Comparison of performance of various sphygmomanometers with intra-arterial blood-pressure readings.

Authors:  S N Hunyor; J M Flynn; C Cochineas
Journal:  Br Med J       Date:  1978-07-15

6.  Comparison of the efficacy and pharmacokinetics of conventional propranolol and a long acting preparation of propranolol.

Authors:  W J Leahey; J D Neill; M P Varma; R G Shanks
Journal:  Br J Clin Pharmacol       Date:  1980-01       Impact factor: 4.335

7.  Clinical evaluation of Dinamap 845 automated blood pressure recorder.

Authors:  J H Silas; A T Barker; L E Ramsay
Journal:  Br Heart J       Date:  1980-02

8.  Comparison of the activity and plasma levels of oxprenolol, slow release oxprenolol, long acting propranolol and sotalol.

Authors:  W J Leahey; J D Neill; M P Varma; R G Shanks
Journal:  Eur J Clin Pharmacol       Date:  1980-06       Impact factor: 2.953

9.  Atenolol, sustained-release oxprenolol, and long-acting propranolol in hypertension.

Authors:  J C Petrie; T A Jeffers; O J Robb; A K Scott; J Webster
Journal:  Br Med J       Date:  1980-06-28

10.  Propranolol LA and ambulatory blood pressure.

Authors:  S Mann; M W Craig; V Balasubramanian; E B Raftery
Journal:  Br J Clin Pharmacol       Date:  1980-11       Impact factor: 4.335

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.