Literature DB >> 7362713

Clinical evaluation of Dinamap 845 automated blood pressure recorder.

J H Silas, A T Barker, L E Ramsay.   

Abstract

The Dinamap 845 blood pressure recorder has been evaluated over a wide range of blood pressure by comparison with the Hawksley random zero sphygmomanometer in 32 subjects, six of whom had a cardiac arrhythmia. Group mean radings for systolic and phase 5 diastolic pressure were almost identical but Dinamap diastolic values were on average significantly lower (mean difference 3.4 mmHg) than phase 4 diastolic readings obtained with the Hawksley machine. Correlations between readings with the two instruments were high but the slopes and intercepts of the regression for systolic but not diastolic pressure were significantly different from unity and zero, respectively. The Dinamap is easy to use, portable, and capable of rejecting some motion artefact. Its major disadvantage is that the systolic blood pressure measurement is limited to a maximum of 210 mmHg, a point not made clear in the manufacturer's literature. Nevertheless, the Dinamap 845 is acceptable for blood pressure determinations in subjects who are normotensive or who have mild hypertension.

Entities:  

Mesh:

Year:  1980        PMID: 7362713      PMCID: PMC482263          DOI: 10.1136/hrt.43.2.202

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  6 in total

1.  VARIATION IN ARTERIAL PRESSURE THROUGHOUT THE DAY AND NIGHT.

Authors:  D W RICHARDSON; A J HONOUR; G W FENTON; F H STOTT; G W PICKERING
Journal:  Clin Sci       Date:  1964-06       Impact factor: 6.124

2.  Measurement of blood pressure--a routine test in need of standardization.

Authors:  T Thulin; G Andersson; B Scherstén
Journal:  Postgrad Med J       Date:  1975-06       Impact factor: 2.401

3.  A random-zero sphygmomanometer.

Authors:  B M Wright; C F Dore
Journal:  Lancet       Date:  1970-02-14       Impact factor: 79.321

4.  Noninvasive automatic determination of mean arterial pressure.

Authors:  M Ramsey
Journal:  Med Biol Eng Comput       Date:  1979-01       Impact factor: 2.602

5.  The methodology of blood pressure recording.

Authors:  E B Raftery
Journal:  Br J Clin Pharmacol       Date:  1978-09       Impact factor: 4.335

6.  Comparison of performance of various sphygmomanometers with intra-arterial blood-pressure readings.

Authors:  S N Hunyor; J M Flynn; C Cochineas
Journal:  Br Med J       Date:  1978-07-15
  6 in total
  26 in total

1.  Acute changes in forearm haemodynamics produced by cigarette smoking in healthy normotensive non-smokers are not influenced by propranolol or pindolol.

Authors:  P Brunel; X Girerd; S Laurent; B Pannier; M Safar
Journal:  Eur J Clin Pharmacol       Date:  1992       Impact factor: 2.953

2.  Standard algorithm of blood-pressure measurement by the oscillometric method.

Authors:  A Sapiński
Journal:  Med Biol Eng Comput       Date:  1992-11       Impact factor: 2.602

3.  Blood pressure monitoring: automated oscillometric devices.

Authors:  M Ramsey
Journal:  J Clin Monit       Date:  1991-01

4.  Influence of acetylator status on the haemodynamic effects and pharmacokinetics of cadralazine in healthy subjects.

Authors:  P Brunel; J B Lecaillon; T T Guyene; P Imhof; J Ménard
Journal:  Br J Clin Pharmacol       Date:  1990-05       Impact factor: 4.335

5.  The Dinamap 1846SX automated blood pressure recorder: comparison with the Hawksley random zero sphygmomanometer under field conditions.

Authors:  P H Whincup; N G Bruce; D G Cook; A G Shaper
Journal:  J Epidemiol Community Health       Date:  1992-04       Impact factor: 3.710

6.  Left ventricular performance during psychological stress.

Authors:  D Z Young; J E Dimsdale; R H Moore; M Barlai-Kovach; J B Newell; K A McKusick; C A Boucher; M A Fifer; H W Strauss
Journal:  Eur J Nucl Med       Date:  1989

7.  Cadralazine pharmacokinetics--a pilot study.

Authors:  K Haglund; R Dahlqvist; H Emilsson; G Englund
Journal:  Eur J Clin Pharmacol       Date:  1988       Impact factor: 2.953

8.  Fatigue varies by social class in African Americans but not Caucasian Americans.

Authors:  Wayne A Bardwell; Stephen C Burke; KaMala S Thomas; Christian Carter; Kimberly Weingart; Joel E Dimsdale
Journal:  Int J Behav Med       Date:  2006

9.  Short-term effects of felodipine, a new dihydropyridine, in hypertension.

Authors:  O Andersson; C Bengtsson; D Elmfeldt; K Haglund; T Hedner; P Seideman; K H Sjöberg; E Strömgren; H Aberg; J Ostman
Journal:  Br J Clin Pharmacol       Date:  1984-03       Impact factor: 4.335

10.  Clinical assessment of the neonatal Dinamap 847 during anesthesia in neonates and infants.

Authors:  P M Cullen; J Dye; D G Hughes
Journal:  J Clin Monit       Date:  1987-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.