Literature DB >> 6670504

Compressive strength of tibial cancellous bone. Instron and osteopenetrometer measurements in an autopsy material.

I Hvid, P Christensen, J Søondergaard, P B Christensen, C G Larsen.   

Abstract

The topographic variation of proximal tibial cancellous bone strength was investigated in 12 knees from routine autopsies. Samples from eight knees were tested to compressive failure in an Instron material testing machine, and four knees were tested with the osteopenetrometer, an instrument developed for intraoperative measurement of bone strength. Ultimate stress, elastic modulus and energy absorption of the bone were calculated from the Instron-curves. Mechanical properties varied considerably from knee to knee, but the topographic patterns were remarkably constant. The medial condyle showed the highest strength, the intercondylar area the lowest. On the medial side the bone was strongest at the front, while on the lateral side the reverse was true. The two horizontal levels tested did not differ significantly. The osteopenetrometer measurements closely modelled the pattern of ultimate stress.

Entities:  

Mesh:

Year:  1983        PMID: 6670504     DOI: 10.3109/17453678308992915

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  9 in total

Review 1.  Measuring bone quality.

Authors:  Elisa Torres-del-Pliego; Laia Vilaplana; Roberto Güerri-Fernández; Adolfo Diez-Pérez
Journal:  Curr Rheumatol Rep       Date:  2013-11       Impact factor: 4.592

2.  Tibial component in total knee arthroplasty: To cement or not to cement?

Authors:  P Cherubino; C Castelli; F A Grassi
Journal:  Eur J Orthop Surg Traumatol       Date:  1996-02

3.  Bone strength measurements at the proximal tibia. Penetration tests and epiphyseal compressive strength.

Authors:  I Hvid; J Jensen; S Nielsen
Journal:  Int Orthop       Date:  1986       Impact factor: 3.075

4.  Tibial plateau strength patterns in experimental modular knee replacement.

Authors:  I Hvid; J T Møller
Journal:  Arch Orthop Trauma Surg       Date:  1985

5.  Cancellous bone at the knee: a comparison of two methods of strength measurement.

Authors:  I Hvid
Journal:  Arch Orthop Trauma Surg       Date:  1985

6.  A Pre-clinical Standard Operating Procedure for Evaluating Orthobiologics in an In Vivo Rat Spinal Fusion Model.

Authors:  Andrew L Alejo; Scott McDermott; Yusuf Khalil; Hope C Ball; Gabrielle T Robinson; Ernesto Solorzano; Amanda M Alejo; Jacob Douglas; Trinity K Samson; Jesse W Young; Fayez F Safadi
Journal:  J Orthop Sports Med       Date:  2022-09-05

7.  Standardizing compression testing for measuring the stiffness of human bone.

Authors:  S Zhao; M Arnold; S Ma; R L Abel; J P Cobb; U Hansen; O Boughton
Journal:  Bone Joint Res       Date:  2018-09-15       Impact factor: 5.853

8.  3D-Printed PLA-Bioglass Scaffolds with Controllable Calcium Release and MSC Adhesion for Bone Tissue Engineering.

Authors:  Eva Schätzlein; Christoph Kicker; Nicolas Söhling; Ulrike Ritz; Jonas Neijhoft; Dirk Henrich; Johannes Frank; Ingo Marzi; Andreas Blaeser
Journal:  Polymers (Basel)       Date:  2022-06-13       Impact factor: 4.967

9.  Regional apparent density correlations within the proximal humerus.

Authors:  Jacob M Reeves; Tom Vanasse; Chris Roche; George S Athwal; James A Johnson; Kenneth J Faber; G Daniel G Langohr
Journal:  JSES Int       Date:  2021-02-09
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.