Literature DB >> 6664135

Impedance measurement of individual skin surface electrodes.

S Grimnes.   

Abstract

Mesh:

Year:  1983        PMID: 6664135     DOI: 10.1007/bf02464038

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


× No keyword cloud information.
  13 in total

1.  SKIN IMPEDANCE AND PHASE ANGLE AS A FUNCTION OF FREQUENCY AND CURRENT.

Authors:  R PLUTCHIK; H R HIRSCH
Journal:  Science       Date:  1963-09-06       Impact factor: 47.728

2.  Electrical characteristics of the skin. The impedance of the surface sheath and deep tissues.

Authors:  J C LAWLER; M J DAVIS; E C GRIFFITH
Journal:  J Invest Dermatol       Date:  1960-05       Impact factor: 8.551

3.  Triboelectric interference in the ECG.

Authors:  D H Gordon
Journal:  IEEE Trans Biomed Eng       Date:  1975-05       Impact factor: 4.538

4.  The phase angle of normal human skin.

Authors:  A Barnett
Journal:  J Physiol       Date:  1938-09-16       Impact factor: 5.182

5.  Reducing skin potential motion artefact by skin abrasion.

Authors:  D P Burbank; J G Webster
Journal:  Med Biol Eng Comput       Date:  1978-01       Impact factor: 2.602

6.  Dynamic system for the measurement of electrical skin impedance.

Authors:  Y Yamamoto; T Yamamoto
Journal:  Med Biol Eng Comput       Date:  1979-01       Impact factor: 2.602

7.  60-HZ interference in electrocardiography.

Authors:  J C Huhta; J G Webster
Journal:  IEEE Trans Biomed Eng       Date:  1973-03       Impact factor: 4.538

8.  Signal source impedance of implanted pacemaker electrodes estimated from the spectral ratio between loaded and unloaded electrograms in man.

Authors:  L Mörkrid; O J Ohm; E Hammer
Journal:  Med Biol Eng Comput       Date:  1980-03       Impact factor: 2.602

9.  Time and frequency dependence of disposable ECG electrode-skin impedance.

Authors:  W H Olson; D R Schmincke; B L Henley
Journal:  Med Instrum       Date:  1979 Sep-Oct

10.  The relationship between input impedance and electrode area in recording the Ecg.

Authors:  L A Geddes; L E Baker
Journal:  Med Biol Eng       Date:  1966-09
View more
  24 in total

1.  Changes in skin A.C. impedance parameters in vivo during the percutaneous absorption of local anesthetics.

Authors:  A D Woolfson; G P Moss; D F McCafferty; A Lackermeier; E T McAdams
Journal:  Pharm Res       Date:  1999-03       Impact factor: 4.200

2.  Skin conductance and the stress response from heel stick in preterm infants.

Authors:  H Storm
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2000-09       Impact factor: 5.747

Review 3.  High-quality recording of bioelectric events. Part 1. Interference reduction, theory and practice.

Authors:  A C Metting van Rijn; A Peper; C A Grimbergen
Journal:  Med Biol Eng Comput       Date:  1990-09       Impact factor: 2.602

4.  Prospective investigation into the influence of various stressors on skin impedance.

Authors:  Michael Winterhalter; Jörg Schiller; Sinika Münte; Michael Bund; Ludwig Hoy; Christoph Weilbach; Siegfried Piepenbrock; Niels Rahe-Meyer
Journal:  J Clin Monit Comput       Date:  2007-11-30       Impact factor: 2.502

5.  High-quality recording of bioelectric events. Part 2. Low-noise, low-power multichannel amplifier design.

Authors:  A C Metting van Rijn; A Peper; C A Grimbergen
Journal:  Med Biol Eng Comput       Date:  1991-07       Impact factor: 2.602

6.  Dielectric properties of some keratinised tissues. Part 1: Stratum corneum and nail in situ.

Authors:  O G Martinsen; S Grimnes; O Sveen
Journal:  Med Biol Eng Comput       Date:  1997-05       Impact factor: 2.602

Review 7.  Factors affecting electrode-gel-skin interface impedance in electrical impedance tomography.

Authors:  E T McAdams; J Jossinet; A Lackermeier; F Risacher
Journal:  Med Biol Eng Comput       Date:  1996-11       Impact factor: 2.602

8.  Simultaneous measurement of electrical admittance, blood flow and temperature at the same skin site with a specially designed probe.

Authors:  Z G Qiao; L Mørkrid; S Grimnes
Journal:  Med Biol Eng Comput       Date:  1987-05       Impact factor: 2.602

9.  A compact-sized surface EMG sensor for myoelectric hand prosthesis.

Authors:  Alok Prakash; Shiru Sharma; Neeraj Sharma
Journal:  Biomed Eng Lett       Date:  2019-08-26

10.  Estimation of in vivo water content of the stratum corneum from electrical measurements.

Authors:  Gorm Krogh Johnsen; O G Martinsen; S Grimnes
Journal:  Open Biomed Eng J       Date:  2009-04-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.