Literature DB >> 6641071

Roentgenologic results of total hip arthroplasty. A ten-year follow-up study.

R C Johnston, R D Crowninshield.   

Abstract

A ten-year roentgenologic follow-up study was made of the results of 326 total hip arthroplasties in 256 patients. Seventy-two percent of the living patients are included in the study. Clinical results at ten years were good in 87% of the patients, fair in 7%, and poor in 6%. The incidence of femoral component loosening was 9% at ten years. There was no correlation between femoral component loosening and calcar resorption. The incidence of acetabular component loosening at ten years was 7.9%. Of six hips with calcar resorption greater than 5 mm, three had loose acetabula. Most of these components shown to be loose roentgenologically were clinically asymptomatic. One and one-half percent were revised because of loosening.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6641071

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  6 in total

1.  A scoring system to determine radiological loosening in cemented total hip arthroplasty.

Authors:  D M Dall; I D Learmonth; M Solomon
Journal:  Int Orthop       Date:  1992       Impact factor: 3.075

2.  [The cemented MS-30 stem. A multi-surgeon series of 333 consecutive cases].

Authors:  M Clauss; T Reitzel; M Pritsch; U J Schlegel; R G Bitsch; V Ewerbeck; H Mau; S J Breusch
Journal:  Orthopade       Date:  2006-07       Impact factor: 1.087

3.  Early follow-up for a hybrid total hip arthroplasty using a metal-backed acetabular component designed to reduce "backside" polyethylene wear.

Authors:  Colin E Poole; Shantanu S Patil; Darryl D D'Lima; Clifford W Colwell
Journal:  HSS J       Date:  2005-09

4.  Comparison between straight- and curved-stem Müller femoral prostheses. 5- to 10-year results of 545 total hip replacements.

Authors:  J Wilson-MacDonald; E Morscher
Journal:  Arch Orthop Trauma Surg       Date:  1990       Impact factor: 3.067

5.  What Can We Learn From 20-year Followup Studies of Hip Replacement?

Authors:  Christopher T Martin; John J Callaghan; Yubo Gao; Andrew J Pugely; Steve S Liu; Lucian C Warth; Devon D Goetz
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

6.  Porous Femoral Fixation in Total Hip Arthroplasty with Short Anatomical Stem: Radiographic Evaluation.

Authors:  Suresh Patil; Carrilero Luis; Henry Finn
Journal:  Clin Orthop Surg       Date:  2017-08-04
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.