Literature DB >> 6625256

Steady-state analysis and evaluation of a new thermal sensor for surface measurements of tissue perfusion.

F S Castellana, R Skalak, J M Cho, R B Case.   

Abstract

The steady-state response and operating characteristics of a new thermal sensor for surface measurements of local tissue perfusion have been analyzed theoretically and evaluated in vivo. The flow measurement system incorporates an electrically isolated thin-film thermal sensor, which is maintained at a fixed temperature by high frequency response electronic circuitry. The sensor rests on the tissue surface, and the power required to maintain a fixed probe to tissue temperature elevation is measured and related to tissue blood flow. A theoretical analysis of the steady-state probe response to flow changes was carried out employing the bio-heat-transfer equation and a solution based on Fourier series to describe the temperature distribution within the tissue domain. A comparison of steady-state theory to results obtained from initial experimental tests on the surface of the dog heart, over a perfusion range 0.51 to 2,00 ml/min/g, shows close agreement. The probe demonstrates good sensitivity to flow changes, provides stable and continuous measurements, and appears promising for both research and clinical applications.

Entities:  

Mesh:

Year:  1983        PMID: 6625256     DOI: 10.1007/bf02367494

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  10 in total

1.  A thermal method for the determination of tissue blood flow.

Authors:  T V McCaffrey; R D McCook
Journal:  J Appl Physiol       Date:  1975-07       Impact factor: 3.531

2.  Internal calorimetry in the measurement of blood flow with heated thermocouples.

Authors:  J L LINZELL
Journal:  J Physiol       Date:  1953-08       Impact factor: 5.182

3.  Accurate measurement of skin blood flow by a thermal conductance method.

Authors:  A V Challoner
Journal:  Med Biol Eng       Date:  1975-03

4.  Analysis of tissue and arterial blood temperatures in the resting human forearm.

Authors:  H H PENNES
Journal:  J Appl Physiol       Date:  1948-08       Impact factor: 3.531

5.  Internal calorimetry--assessment of myocardial blood flow and heat production.

Authors:  J Grayson; R L Coulson; B Winchester
Journal:  J Appl Physiol       Date:  1971-02       Impact factor: 3.531

6.  Left ventricular energetics. Heat loss and temperature distribution of canine myocardium.

Authors:  G H ten Velden; G Elzinga; N Westerhof
Journal:  Circ Res       Date:  1982-01       Impact factor: 17.367

7.  Local blood flow in kidney tissue by heat clearance measurement.

Authors:  W Perl; R L Hirsch
Journal:  J Theor Biol       Date:  1966-02       Impact factor: 2.691

8.  Regional blood flow in the cerebral cortex, measured simultaneously by heat and inert gas clearance.

Authors:  E Betz; D H Ingvar; N A Lassen; F W Schmahl
Journal:  Acta Physiol Scand       Date:  1966-05

9.  Regional myocardial blood flow in awake dogs.

Authors:  F R Cobb; R J Bache; J C Greenfield
Journal:  J Clin Invest       Date:  1974-06       Impact factor: 14.808

10.  Simultaneous regional myocardial blood flows by tritiated water and microspheres.

Authors:  M R Tripp; W Meyer; S Einzig; J J Leonard; C R Swayze; I J Fox
Journal:  Am J Physiol       Date:  1977-02
  10 in total
  5 in total

1.  Simultaneous measurement of skin blood flow by the transient thermal-clearance method and laser Doppler flowmetry.

Authors:  M Nitzan; S L Fairs; V C Roberts
Journal:  Med Biol Eng Comput       Date:  1988-07       Impact factor: 2.602

2.  Theoretical analysis of the transient thermal clearance method for regional blood flow measurement.

Authors:  M Nitzan; Y Mahler
Journal:  Med Biol Eng Comput       Date:  1986-11       Impact factor: 2.602

3.  Thermal method for continuous measurement of cerebral perfusion.

Authors:  D Wei; G M Saidel; S C Jones
Journal:  Med Biol Eng Comput       Date:  1994-09       Impact factor: 2.602

4.  Non-Invasive Blood Perfusion Measurements Using a Combined Temperature and Heat Flux Surface Probe.

Authors:  Patricia L Ricketts; Ashvinikumar V Mudaliar; Brent E Ellis; Clay A Pullins; Leah A Meyers; Otto I Lanz; Elaine P Scott; Thomas E Diller
Journal:  Int J Heat Mass Transf       Date:  2008-11-01       Impact factor: 5.584

5.  Noninvasive blood perfusion measurements of an isolated rat liver and an anesthetized rat kidney.

Authors:  Ashvinikumar V Mudaliar; Brent E Ellis; Patricia L Ricketts; Otto I Lanz; Charles Y Lee; Thomas E Diller; Elaine P Scott
Journal:  J Biomech Eng       Date:  2008-12       Impact factor: 2.097

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.