Literature DB >> 3657316

Theoretical analysis of the transient thermal clearance method for regional blood flow measurement.

M Nitzan, Y Mahler.   

Abstract

Mesh:

Year:  1986        PMID: 3657316     DOI: 10.1007/bf02446262

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


× No keyword cloud information.
  9 in total

1.  The blood flow in skin and muscle of the human forearm.

Authors:  K E COOPER; O G EDHOLM; R F MOTTRAM
Journal:  J Physiol       Date:  1955-05-27       Impact factor: 5.182

2.  Regional differences in the basal and maximal rates of blood flow in the skin.

Authors:  A B HERTZMAN; W C RANDALL
Journal:  J Appl Physiol       Date:  1948-09       Impact factor: 3.531

3.  The theory and applications of the exchange of inert gas at the lungs and tissues.

Authors:  S S KETY
Journal:  Pharmacol Rev       Date:  1951-03       Impact factor: 25.468

4.  A mathematical model of the human temperature regulatory system--transient cold exposure response.

Authors:  R G Gordon; R B Roemer; S M Horvath
Journal:  IEEE Trans Biomed Eng       Date:  1976-11       Impact factor: 4.538

Review 5.  Radioisotopic assessment of regional cerebral blood flow.

Authors:  N A Lassen; D H Ingvar
Journal:  Prog Nucl Med       Date:  1972

6.  Measurements of the thermal conductivity of the skin as an indication of skin blood flow.

Authors:  W J van de Staak; A J Brakkee; H E Rijke-Herweijer
Journal:  J Invest Dermatol       Date:  1968-09       Impact factor: 8.551

7.  Steady-state analysis and evaluation of a new thermal sensor for surface measurements of tissue perfusion.

Authors:  F S Castellana; R Skalak; J M Cho; R B Case
Journal:  Ann Biomed Eng       Date:  1983       Impact factor: 3.934

8.  Transient heat clearance method for regional blood flow measurements.

Authors:  M Nitzan; S O Anteby; Y Mahler
Journal:  Phys Med Biol       Date:  1985-06       Impact factor: 3.609

Review 9.  H2 clearance measurement of blood flow: a review of technique and polarographic principles.

Authors:  W Young
Journal:  Stroke       Date:  1980 Sep-Oct       Impact factor: 7.914

  9 in total
  5 in total

1.  Microprocessor automatic multiple temperature measurement device.

Authors:  Y Mahler; N Lifshitz; M Nitzan
Journal:  Med Biol Eng Comput       Date:  1988-09       Impact factor: 2.602

2.  Simultaneous measurement of skin blood flow by the transient thermal-clearance method and laser Doppler flowmetry.

Authors:  M Nitzan; S L Fairs; V C Roberts
Journal:  Med Biol Eng Comput       Date:  1988-07       Impact factor: 2.602

3.  Faster procedure for deriving regional blood flow by the noninvasive transient thermal clearance method.

Authors:  M Nitzan; Y Mahler; N Lifshitz
Journal:  Ann Biomed Eng       Date:  1993 May-Jun       Impact factor: 3.934

4.  Photoacoustic thermal diffusion flowmetry.

Authors:  Adi Sheinfeld; Avishay Eyal
Journal:  Biomed Opt Express       Date:  2012-03-29       Impact factor: 3.732

5.  Epidermal devices for noninvasive, precise, and continuous mapping of macrovascular and microvascular blood flow.

Authors:  R Chad Webb; Yinji Ma; Siddharth Krishnan; Yuhang Li; Stephen Yoon; Xiaogang Guo; Xue Feng; Yan Shi; Miles Seidel; Nam Heon Cho; Jonas Kurniawan; James Ahad; Niral Sheth; Joseph Kim; James G Taylor; Tom Darlington; Ken Chang; Weizhong Huang; Joshua Ayers; Alexander Gruebele; Rafal M Pielak; Marvin J Slepian; Yonggang Huang; Alexander M Gorbach; John A Rogers
Journal:  Sci Adv       Date:  2015-10-30       Impact factor: 14.136

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.