Literature DB >> 6624679

Noninvasive determination of systolic, diastolic and end-systolic blood pressure in neonates, infants and young children: comparison with central aortic pressure measurements.

S D Colan, A Fujii, K M Borow, D MacPherson, S P Sanders.   

Abstract

Noninvasive determinations of systolic and diastolic blood pressure using the oscillometric method for pressure measurement were combined with externally recorded axillary pulse tracings to estimate end-systolic pressure in 32 neonates, infants and young children. Results were compared with central aortic pressure measurements made at the time of central aortic catheter placement. Studies were performed in patients aged 1 day to 48 months who weighed 0.9 to 18.1 kg. A wide range of systolic (41 to 141 mm Hg), diastolic (22 to 73 mm Hg) and end-systolic (30 to 111 mm Hg) pressure values were found. The mean absolute pressure differences and percent errors (pressure difference divided by central aortic pressure) were 1.8 mm Hg and 2.5% for systolic, 0.8 mm Hg and 0.8% for diastolic and 1.4 mm Hg and 2.1% for end-systolic pressure. No correlation was noted between percent error and age, weight, heart rate, cardiac index or systemic vascular resistance. The ability to perform reliable noninvasive pressure measurements should prove invaluable for clinical and research purposes. In addition, this method of end-systolic blood pressure determination enables sensitive indexes of left ventricular contractility to be measured noninvasively in small children.

Entities:  

Mesh:

Year:  1983        PMID: 6624679     DOI: 10.1016/0002-9149(83)90430-7

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  13 in total

1.  Accuracy of four indirect methods of blood pressure measurement, with hemodynamic correlations.

Authors:  G P Gravlee; J K Brockschmidt
Journal:  J Clin Monit       Date:  1990-10

Review 2.  Are pitfalls of oxcillometric blood pressure measurements preventable in children?

Authors:  Lavjay Butani; Bruce Z Morgenstern
Journal:  Pediatr Nephrol       Date:  2003-04       Impact factor: 3.714

3.  Blood pressure in non-critically ill preterm and full-term neonates.

Authors:  Bijana Pejovic; Amira Peco-Antic; Jelena Marinkovic-Eric
Journal:  Pediatr Nephrol       Date:  2006-10-20       Impact factor: 3.714

4.  Noninvasive measurement of aortic pressure waveform by ultrasound.

Authors:  H Watanabe; M Kawai; T Sibata; M Hara; H Furuhata; S Mochizuki
Journal:  Heart Vessels       Date:  1998       Impact factor: 2.037

Review 5.  How to assess hemodynamic status in very preterm newborns in the first week of life?

Authors:  G Escourrou; L Renesme; E Zana; A Rideau; M O Marcoux; E Lopez; G Gascoin; P Kuhn; P Tourneux; I Guellec; C Flamant
Journal:  J Perinatol       Date:  2017-05-04       Impact factor: 2.521

6.  The Dinamap 1846SX automated blood pressure recorder: comparison with the Hawksley random zero sphygmomanometer under field conditions.

Authors:  P H Whincup; N G Bruce; D G Cook; A G Shaper
Journal:  J Epidemiol Community Health       Date:  1992-04       Impact factor: 3.710

7.  Non-invasive oscillometric measurement of systolic, mean and diastolic blood pressure in infants with congenital heart defects after operation. A comparison with direct blood pressure measurements.

Authors:  V Pilossoff; J G Schöber; D Peters; K Bühlmeyer
Journal:  Eur J Pediatr       Date:  1985-11       Impact factor: 3.183

8.  Systolic blood pressure in babies of less than 32 weeks gestation in the first year of life. Northern Neonatal Nursing Initiative.

Authors: 
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1999-01       Impact factor: 5.747

9.  Renal venous thrombosis in infancy: long-term follow-up.

Authors:  H Mocan; T J Beattie; A V Murphy
Journal:  Pediatr Nephrol       Date:  1991-01       Impact factor: 3.714

10.  Clinical assessment of the neonatal Dinamap 847 during anesthesia in neonates and infants.

Authors:  P M Cullen; J Dye; D G Hughes
Journal:  J Clin Monit       Date:  1987-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.