Literature DB >> 6589244

Reproducibility of probing attachment level measurements.

A Badersten, R Nilvéus, J Egelberg.   

Abstract

The reproducibility of probing attachment level measurements in incisors, cuspids and premolars was studied in 2 groups of patients with severely advanced periodontal disease. The results showed that approximately 90% of the recordings could be reproduced within within +/- 1.0 mm difference. This was found for intra-examiner as well as inter-examiner comparisons of 2 examiners. Measurements using onlay margins for reference point demonstrated somewhat less variability than the use of cemento-enamel junction for reference. The level of reproducibility varied notably between patients and was improved following non-surgical periodontal therapy. Also, the reproducibility varied significantly between tooth types, tooth surfaces and probing pocket depths. It was concluded that in clinical studies, the evaluation of the healing response of individual lesions should include consideration of the variability of repeated measurements for each of the investigated tooth sites.

Entities:  

Mesh:

Year:  1984        PMID: 6589244     DOI: 10.1111/j.1600-051x.1984.tb01347.x

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  17 in total

1.  Effectiveness of a personalized device in the evaluation of mandibular second molar periodontal healing after surgical extraction of adjacent third molar.

Authors:  Roberto Pippi
Journal:  Ann Stomatol (Roma)       Date:  2014-02-04

2.  Evaluation of an Electronic Periodontal Probe Versus a Manual Probe.

Authors:  Antonio Renatus; Lars Trentzsch; Antje Schönfelder; Fabian Schwarzenberger; Holger Jentsch
Journal:  J Clin Diagn Res       Date:  2016-11-01

3.  Efficacy of concentrated growth factor with low-level laser for the regeneration of interdental papilla defects.

Authors:  Ziling Chen; Di Miao; Le Zhang; Liangqiuyue Zhong; Na Liu; Yue Chen
Journal:  Odontology       Date:  2022-03-15       Impact factor: 2.885

4.  Alterations of the marginal soft tissue (gingival margin) following periodontal therapy: A clinical study.

Authors:  Ira Gupta; K L Vandana
Journal:  J Indian Soc Periodontol       Date:  2009-05

5.  The location of cemento enamel junction for CAL measurement: A clinical crisis.

Authors:  K L Vandana; Ira Gupta
Journal:  J Indian Soc Periodontol       Date:  2009-01

6.  Comparative evaluation of accuracy of periodontal probing depth and attachment levels using a Florida probe versus traditional probes.

Authors:  Nitin Gupta; S K Rath; Parul Lohra
Journal:  Med J Armed Forces India       Date:  2012-10-23

7.  Assessment of Intra- and Inter-examiner Reproducibility of Probing Depth Measurements with a Manual Periodontal Probe.

Authors:  Ardeshir Lafzi; Adileh Shir Mohammadi; Amir Eskandari; Sohrab Pourkhamneh
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2007-06-10

8.  Predictive factors for dental inflammation with exacerbation during cancer therapy with FDG-PET/CT imaging.

Authors:  Mai Kim; Trang Thuy Dam; Masaru Ogawa; Takahiro Shimizu; Takahiro Yamaguchi; Keisuke Suzuki; Takuya Asami; Jun Kurihara; Satoshi Yokoo
Journal:  Support Care Cancer       Date:  2021-01-07       Impact factor: 3.359

9.  Clinical attachment loss: estimation by direct and indirect methods.

Authors:  Viviane Leal Barbosa; Patricia D Melchiors Angst; Amanda Finger Stadler; Rui V Oppermann; Sabrina Carvalho Gomes
Journal:  Int Dent J       Date:  2016-02-05       Impact factor: 2.607

10.  Comparative assessment of conventional periodontal probes and CEJ handpiece of electronic probes in the diagnosis and primary care of periodontal disease.

Authors:  Harshita Bareja; Monika Bansal; P G Naveen Kumar
Journal:  J Family Med Prim Care       Date:  2021-02-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.