Literature DB >> 6577793

Measurability of radiographic images.

D H Tsao, A Kazanoglu, J P McCasland.   

Abstract

Projective distortion has been recognized since the first attempts were made to measure images on x-ray films. However, the nature of this distortion has not been thoroughly investigated by the dental profession. Part of the difficulty in addressing the problem is the necessity of the researcher's having knowledge and training in nonmetric mathematical thinking. To demonstrate the nonmetric nature of projective transformation, seven precision line gauges were made of glass tubes filled with steel balls 1/8 inch in diameter and were attached to a skull at various locations. Cephalometric x-ray films of the prepared skull with gauges in place were taken to simulate lateral and other views. The image lengths of the gauges were directly measured from the x-ray films. The results showed that the image length can be longer, shorter, or the same as the object gauge and cannot be predicted, corrected, or compensated for from the images alone. Linear projective transformation measured in this study ranged from 7.32 percent elongation to 69.63 percent foreshortening. Thus, it is illogical to measure radiographic images without restrictions. The basic limitation of measuring radiographic images on x-ray film is that the parallel relation must be established between the object line (or plane) and the image line (or plane). Technical restrictions should be established as a convention by those who have had the most experience in using radiographic measurements.

Mesh:

Year:  1983        PMID: 6577793     DOI: 10.1016/0002-9416(83)90128-8

Source DB:  PubMed          Journal:  Am J Orthod        ISSN: 0002-9416


  5 in total

Review 1.  The current status of cone beam computed tomography imaging in orthodontics.

Authors:  S Kapila; R S Conley; W E Harrell
Journal:  Dentomaxillofac Radiol       Date:  2011-01       Impact factor: 2.419

2.  Geometric analysis of alveolar bone around the incisors after anterior retraction following premolar extraction.

Authors:  Fan Zhang; Suk-Cheol Lee; Jun-Beom Lee; Kyung-Min Lee
Journal:  Angle Orthod       Date:  2019-11-26       Impact factor: 2.079

3.  Validation of Osteoarthritis synthetic defect database via non-rigid registration.

Authors:  Beatriz Paniagua; Juliette Pera; Francois Budin; Liliane Gomes; Martin Styner; Cevidanes Lucia; Tung Nguyen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-17

4.  Cone-beam computed tomography: An inevitable investigation in cleidocranial dysplasia.

Authors:  Nandita S Gupta; Ajas A Gogri; Manasi M Kajale; Sonali G Kadam
Journal:  Contemp Clin Dent       Date:  2015 Apr-Jun

5.  Digital orthodontic radiographic set versus cone-beam computed tomography: an evaluation of the effective dose.

Authors:  Lillian Atsumi Simabuguro Chinem; Beatriz de Souza Vilella; Cláudia Lúcia de Pinho Maurício; Lucia Viviana Canevaro; Luiz Fernando Deluiz; Oswaldo de Vasconcellos Vilella
Journal:  Dental Press J Orthod       Date:  2016 Jul-Aug
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.