Literature DB >> 6571572

Driven-equilibrium radiofrequency pulses in NMR imaging.

C M van Uijen, J H den Boef.   

Abstract

Driven-equilibrium pulse techniques are applied to NMR imaging to extend the possibilities of manipulating image contrasts in pulse sequences with a high repetition rate. In many cases the data acquisition time can be much shorter than in more conventional pulse techniques. Both calculations and experiments reveal that the intensity of tissue with slowly relaxing nuclear magnetizations can significantly be enhanced, thus facilitating the detection of a number of pathologies.

Mesh:

Year:  1984        PMID: 6571572     DOI: 10.1002/mrm.1910010409

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  11 in total

1.  A new pulse sequence to visualize slow flow.

Authors:  K-I Gjesdal; J C Hellund; T Storaas; J-T Geitung
Journal:  MAGMA       Date:  2004-08-30       Impact factor: 2.310

2.  MDEFT imaging of the human brain at 8 T.

Authors:  D G Norris; A Kangarlu; C Schwarzbauer; A M Abduljalil; G Christoforidis; P M Robitaille
Journal:  MAGMA       Date:  1999-10       Impact factor: 2.310

3.  Contrast-modified gradient echo imaging using rotary echo preparatory pulses.

Authors:  X P Zhu; P B Chilvers; C E Hutchinson; G A Morris; J M Hawnaur; J E Adams; C J Taylor
Journal:  MAGMA       Date:  1997-09       Impact factor: 2.310

4.  Whole-brain three-dimensional T2-weighted BOLD functional magnetic resonance imaging at 7 Tesla.

Authors:  Jun Hua; Qin Qin; Peter C M van Zijl; James J Pekar; Craig K Jones
Journal:  Magn Reson Med       Date:  2013-12-12       Impact factor: 4.668

5.  Spatiotemporal encoding as a robust basis for fast three-dimensional in vivo MRI.

Authors:  Noam Ben-Eliezer; Lucio Frydman
Journal:  NMR Biomed       Date:  2011-02-28       Impact factor: 4.044

6.  Accelerated radiation damping for increased spin equilibrium (ARISE): a new method for controlling the recovery of longitudinal magnetization.

Authors:  Susie Y Huang; Thomas Witzel; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2008-11       Impact factor: 4.668

7.  MRI of slow flow in artificial duct in swine.

Authors:  Johan Castberg Hellund; Knut Jørgen Labori; Bjørn Atle Bjørnbeth; Kjell Inge Gjesdal; Jonn Terje Geitung
Journal:  Eur Radiol       Date:  2004-02-07       Impact factor: 5.315

8.  Interleaved quantitative BOLD: Combining extravascular R2' - and intravascular R2-measurements for estimation of deoxygenated blood volume and hemoglobin oxygen saturation.

Authors:  Hyunyeol Lee; Erin K Englund; Felix W Wehrli
Journal:  Neuroimage       Date:  2018-03-23       Impact factor: 6.556

9.  Characterization of lenticulostriate arteries with high resolution black-blood T1-weighted turbo spin echo with variable flip angles at 3 and 7 Tesla.

Authors:  Samantha J Ma; Mona Sharifi Sarabi; Lirong Yan; Xingfeng Shao; Yue Chen; Qi Yang; Kay Jann; Arthur W Toga; Yonggang Shi; Danny J J Wang
Journal:  Neuroimage       Date:  2019-05-31       Impact factor: 7.400

10.  Characteristics of spondylotic myelopathy on 3D driven-equilibrium fast spin echo and 2D fast spin echo magnetic resonance imaging: a retrospective cross-sectional study.

Authors:  Mike A Abdulhadi; Joseph R Perno; Elias R Melhem; Paolo G P Nucifora
Journal:  PLoS One       Date:  2014-07-15       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.