Literature DB >> 15340857

A new pulse sequence to visualize slow flow.

K-I Gjesdal1, J C Hellund, T Storaas, J-T Geitung.   

Abstract

The purpose of this paper is to present a new pulse sequence for visualizing slow flow. The new sequence consists of an initial Stejskal-Tanner flow sensitization part followed by a DEFT pulse and a spoiler gradient. A single-shot TSE readout train is then applied to sample the NMR signal. The sequence was initially tested using a simple flow phantom. To verify potential clinical use, both flow-sensitive MRCP and cerebrospinal fluid (CSF) images were produced. The phantom study proved the sequence sensitivity to flow in the range 0-1 cm/s. bVE-factors 1.5, 3, 6 and 12 were chosen. Within this flow velocity range, the signal dropped as predicted theoretically. This indicates that the method can be used to quantify flow. All anatomical features seen in a standard MRCP sequence were identified and the methods sensitivity to CSF flow was demonstrated by sagital images of the head. A new pulse sequence sensitive to slow flow has been developed.

Mesh:

Year:  2004        PMID: 15340857     DOI: 10.1007/s10334-004-0045-9

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  7 in total

1.  On the application of ultra-fast RARE experiments.

Authors:  D G Norris; P Börnert; T Reese; D Leibfritz
Journal:  Magn Reson Med       Date:  1992-09       Impact factor: 4.668

Review 2.  Molecular diffusion nuclear magnetic resonance imaging.

Authors:  D Le Bihan
Journal:  Magn Reson Q       Date:  1991-01

3.  Phase insensitive preparation of single-shot RARE: application to diffusion imaging in humans.

Authors:  D C Alsop
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

4.  SPLICE: sub-second diffusion-sensitive MR imaging using a modified fast spin-echo acquisition mode.

Authors:  F Schick
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

5.  Three-dimensional phase contrast angiography.

Authors:  C L Dumoulin; S P Souza; M F Walker; W Wagle
Journal:  Magn Reson Med       Date:  1989-01       Impact factor: 4.668

6.  Driven-equilibrium radiofrequency pulses in NMR imaging.

Authors:  C M van Uijen; J H den Boef
Journal:  Magn Reson Med       Date:  1984-12       Impact factor: 4.668

7.  Cerebrospinal fluid dynamics and relation with blood flow: a magnetic resonance study with semiautomated cerebrospinal fluid segmentation.

Authors:  O Balédent; M C Henry-Feugeas; I Idy-Peretti
Journal:  Invest Radiol       Date:  2001-07       Impact factor: 6.016

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.