Literature DB >> 6549359

Assessment of bone viability after heat trauma. A histological, histochemical and vital microscopic study in the rabbit.

R A Eriksson, T Albrektsson, B Magnusson.   

Abstract

In the present investigation a comparison was made between conventional histology, histochemistry and vital microscopy for assessment of heat-induced bone tissue injury. The extent of the bone damage around a burr hole or after heating fibular bone samples in saline solutions of various temperatures was evaluated by means of histology and histochemistry, using the absence of filled osteocyte lacunae or lack of oxidative enzyme activities as indication of bone death, respectively. In both cases a wider necrotic border zone was detected with histochemistry than with histology. The vital microscopic method is based on a titanium chamber which, after insertion in the rabbit tibia, allows observation and registration of the same bone compartment for a follow-up period of more than one year. The dynamic tissue events taking place after heating to 50 degrees C for one minute were investigated and compared with histological and histochemical data of the bone. The vital microscopic method showed a consistent and widespread bone tissue injury after heating to 50 degrees C for one minute while, on the other hand, the indirect methods exhibited only inconsistent signs of tissue injury. It is concluded that histochemistry using the presence or otherwise of diaphorase enzyme activities is a more reliable method than is histology for the estimation of bone viability after heat trauma. Vital microscopy is more sensitive than indirect, morphologic and metabolic techniques for detection of heat-induced bone tissue injury.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6549359     DOI: 10.3109/02844318409052849

Source DB:  PubMed          Journal:  Scand J Plast Reconstr Surg        ISSN: 0036-5556


  57 in total

Review 1.  Percutaneous vertebroplasty: a developing standard of care for vertebral compression fractures.

Authors:  J M Mathis; J D Barr; S M Belkoff; M S Barr; M E Jensen; H Deramond
Journal:  AJNR Am J Neuroradiol       Date:  2001-02       Impact factor: 3.825

2.  Bone cements: review of their physiochemical and biochemical properties in percutaneous vertebroplasty.

Authors:  Matthew J Provenzano; Kieran P J Murphy; Lee H Riley
Journal:  AJNR Am J Neuroradiol       Date:  2004-08       Impact factor: 3.825

3.  [Filler materials for augmentation of osteoporotic vertebral fractures].

Authors:  M Arabmotlagh; M Rauschmann
Journal:  Orthopade       Date:  2010-07       Impact factor: 1.087

4.  Study of temperature variation in cortical bone during osteotomies with trephine drills.

Authors:  Sergio Alexandre Gehrke; Marcelo Khoury Pazetto; Sérgio de Oliveira; Stefano Corbella; Silvio Taschieri; Fábio E C Mardegan
Journal:  Clin Oral Investig       Date:  2014-01-08       Impact factor: 3.573

5.  Direct and interactive effects of three variables on properties of PMMA bone cement for vertebral body augmentation.

Authors:  Alejandro López; Erik Unosson; Håkan Engqvist; Cecilia Persson
Journal:  J Mater Sci Mater Med       Date:  2011-04-28       Impact factor: 3.896

6.  Temperature change during non-contact diode laser irradiation of implant surfaces.

Authors:  Alessandro Geminiani; Jack G Caton; Georgios E Romanos
Journal:  Lasers Med Sci       Date:  2011-01-28       Impact factor: 3.161

7.  Thermal denaturation studies of collagen by microthermal analysis and atomic force microscopy.

Authors:  Laurent Bozec; Marianne Odlyha
Journal:  Biophys J       Date:  2011-07-06       Impact factor: 4.033

Review 8.  Heat generated by dental implant drills during osteotomy-a review: heat generated by dental implant drills.

Authors:  Sunil Kumar Mishra; Ramesh Chowdhary
Journal:  J Indian Prosthodont Soc       Date:  2014-02-18

9.  Temperature Rise in Kirschner Wires Inserted Using Two Drilling Methods: Forward and Oscillation.

Authors:  Scott Richard Anderson; Serkan Inceoglu; Montri D Wongworawat
Journal:  Hand (N Y)       Date:  2017-05-16

10.  Hammering K-wires is superior to drilling with irrigation.

Authors:  Bas B G M Franssen; Arnold H Schuurman; Pascal C R Brouha; Moshe Kon
Journal:  Hand (N Y)       Date:  2008-12-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.