Literature DB >> 6528102

Scaling respiratory pattern and respiratory 'drive'.

D F Boggs, S M Tenney.   

Abstract

We tested three predictions regarding the relationship between body size and respiratory 'drive' and timing in mammals. Mechanical considerations had led to the prediction that TE/TTOT and probably TI/TTOT would be interspecific constants. In eleven species of mammals, ranging in size from 0.033 kg to 520 kg, TE/TTOT during awake quiet breathing was an interspecific constant with a value of 0.65 (+/- 0.004); TI/TTOT was 0.345 (+/- 0.004). Given that VT is directly proportional to BW1.0 (Stahl, 1967), if TE and TI are directly proportional to BW0.28 (Bennett and Tenney, 1982), and if VT/TI is an index of respiratory 'drive', then 'drive' should be directly proportional to BW0.72, following the same proportionality with body size as does basal metabolic rate (VO2). Data for the same eleven species gave the relationship VT/TI BW0.74. Testing further the notion that 'drive', on a weight specific basis, is proportional to BW-0.26, we studied the response, % delta VI, in eleven species to approximately 12% inspired O2. This 'output' of the system in response to a hypoxic stimulus was found to scale with BW-0.27. The question whether this reflects a higher set 'gain' of the respiratory controller of smaller animals and/or some feature of the innervation, or intrinsic properties of the respiratory muscles that varies with body size is discussed.

Entities:  

Mesh:

Year:  1984        PMID: 6528102     DOI: 10.1016/0034-5687(84)90001-x

Source DB:  PubMed          Journal:  Respir Physiol        ISSN: 0034-5687


  6 in total

1.  Influence of anthropometric characteristics on changes in maximal exercise ventilation and breathing pattern during growth in boys.

Authors:  J Mercier; A Varray; M Ramonatxo; B Mercier; C Préfaut
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1991

2.  Human hypoglossal motor unit activities in exercise.

Authors:  Clinton E Walls; Christopher M Laine; Ian J Kidder; E Fiona Bailey
Journal:  J Physiol       Date:  2013-05-20       Impact factor: 5.182

3.  A comprehensive assessment of genioglossus electromyographic activity in healthy adults.

Authors:  Jennifer R Vranish; E Fiona Bailey
Journal:  J Neurophysiol       Date:  2015-02-18       Impact factor: 2.714

4.  Ventilatory and metabolic responses of a bat, Phyllostomus discolor, to hypoxia and CO2: implications for the allometry of respiratory control.

Authors:  J P Walsh; D F Boggs; D L Kilgore
Journal:  J Comp Physiol B       Date:  1996       Impact factor: 2.200

5.  Cardiorespiratory responses of the woodchuck and porcupine to CO2 and hypoxia.

Authors:  D F Boggs; G F Birchard
Journal:  J Comp Physiol B       Date:  1989       Impact factor: 2.200

6.  Minute ventilation during mask halothane anaesthesia in infants and children.

Authors:  K A Brown; B Bissonnette; H Holtby; S Ein; B Shandling
Journal:  Can J Anaesth       Date:  1993-02       Impact factor: 5.063

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.