Literature DB >> 6524325

Stability of acetabular fractures after internal fixation. A cadaveric study.

T Sawaguchi, T D Brown, H E Rubash, D C Mears.   

Abstract

The rigidity of a transverse acetabular fracture in a laboratory cadaveric model immobilized by internal fixation was studied. On the application of a longitudinal load imposed on the fifth lumbar vertebra, four modes of displacement of the acetabular fracture were monitored by the use of variable impedance transducers. The rigidity of various combinations of lag screws and plates was assessed. The fracture deformations documented were generally quite small at any observation point with any of the fixation methods, and in most cases they were recoverable on load release. Anterior column lag screw fixation combined with plate fixation of the posterior column provided a degree of stability indistinguishable from that of other methods, and allowed the minimal exposure and devascularization of the pelvis. The 3.5 mm reconstruction plate, which is readily contoured to the intricate peri-acetabular bony structure, showed no significant difference in rigidity compared to the other apparently more rigid plates under study.

Entities:  

Mesh:

Year:  1984        PMID: 6524325     DOI: 10.3109/17453678408992404

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  11 in total

1.  Biomechanical comparison of methods of fixation of isolated osteotomies of the posterior acetabular column.

Authors:  A Schopfer; D DiAngelo; T Hearn; J Powell; M Tile
Journal:  Int Orthop       Date:  1994-04       Impact factor: 3.075

Review 2.  [Biomechanical principles for treatment of osteoporotic fractures of the pelvis].

Authors:  A Gänsslen
Journal:  Unfallchirurg       Date:  2010-04       Impact factor: 1.000

3.  Are quadrilateral surface buttress plates comparable to traditional forms of transverse acetabular fracture fixation?

Authors:  Brian J Kistler; Ian R Smithson; Seth A Cooper; Jacob L Cox; Aniruddh N Nayak; Brandon G Santoni; H Claude Sagi
Journal:  Clin Orthop Relat Res       Date:  2014-11       Impact factor: 4.176

4.  Biomechanical comparison of different stabilization constructs for unstable posterior wall fractures of acetabulum. A cadaveric study.

Authors:  Yuntong Zhang; Yang Tang; Panfeng Wang; Xue Zhao; Shuogui Xu; Chuncai Zhang
Journal:  PLoS One       Date:  2013-12-31       Impact factor: 3.240

5.  A novel fixation system for acetabular quadrilateral plate fracture: a comparative biomechanical study.

Authors:  Guo-Chun Zha; Jun-Ying Sun; Sheng-Jie Dong; Wen Zhang; Zong-Ping Luo
Journal:  Biomed Res Int       Date:  2015-01-31       Impact factor: 3.411

6.  Biomechanical analysis of the fixation systems for anterior column and posterior hemi-transverse acetabular fractures.

Authors:  Jianyin Lei; Pengfei Dong; Zhiqiang Li; Feng Zhu; Zhihua Wang; Xianhua Cai
Journal:  Acta Orthop Traumatol Turc       Date:  2017-03-23       Impact factor: 1.511

7.  Comparison of Biomechanical Performance of Five Different Treatment Approaches for Fixing Posterior Pelvic Ring Injury.

Authors:  Yongtao Lu; Yiqian He; Weiteng Li; Zhuoyue Yang; Ruifei Peng; Li Yu
Journal:  J Healthc Eng       Date:  2020-01-22       Impact factor: 2.682

8.  The Influence of Pelvic Ramus Fracture on the Stability of Fixed Pelvic Complex Fracture.

Authors:  Jianyin Lei; Yue Zhang; Guiying Wu; Zhihua Wang; Xianhua Cai
Journal:  Comput Math Methods Med       Date:  2015-10-01       Impact factor: 2.238

9.  Biomechanical Analysis of the Fixation System for T-Shaped Acetabular Fracture.

Authors:  Yanping Fan; Jianyin Lei; Feng Zhu; Zhiqiang Li; Weiyi Chen; Ximing Liu
Journal:  Comput Math Methods Med       Date:  2015-10-01       Impact factor: 2.238

10.  Posterior column acetabular fracture fixation using a W-shaped angular plate: A biomechanical analysis.

Authors:  Ke Su; Song Liu; Tao Wu; Yingchao Yin; Ruipeng Zhang; Shilun Li; Yingze Zhang
Journal:  PLoS One       Date:  2017-11-20       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.