Literature DB >> 651281

[A simplified radioimmunoassay for digoxin determination using a 125-j-labelled, solid-phase kit (author's transl)].

W Doering, E Blümel.   

Abstract

Our experience with a commercially available kit (Radioimmunoassay DIGOXIN, Boehringer, Mannheim) using (125J)-labelled digoxin and antibody-coated tubes is reported. This simplified method requires only two pepetting steps per sample and results can be obtained in 70 min. The intra- and interassay coefficient of variation ranged between 7% and 8%. The specific digoxin antibody gave no clinical relevant cross-reactions with spironolactone or prednisone (less than 0.0007%). Of the digoxin metabolites the aglucone digoxigenin showed 31% cross-reaction while the more important cardioactive metabolites digoxigenin-bis- and mono-digitoxide had the same binding affinity to the antibody as digoxin, beta-methyldigoxin and beta-acetyldigoxin. Cross-reaction with digitoxin was 6.8%. More than double-fold dilution of serum protein concentration showed little influence on the digoxin values measured. The results obtained by this new kit compare closely with those obtained by our tritium-labelled kit (r = 0.94, p less than 0.001). Therefore, the upper therapeutic limit of 1.9 ng/ml can be adopted for this method.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 651281     DOI: 10.1007/BF01492862

Source DB:  PubMed          Journal:  Klin Wochenschr        ISSN: 0023-2173


  21 in total

Review 1.  Digitalis intoxication--diagnosis, management and prevention.

Authors:  G A Ewy; F I Marcus; S J Fillmore; N P Matthews
Journal:  Cardiovasc Clin       Date:  1974

2.  A rapid, simple assay for digoxin.

Authors:  H Greenwood; M Howard; J Landon
Journal:  J Clin Pathol       Date:  1974-06       Impact factor: 3.411

3.  Variability of standard curves in radioimmunoassay of plasma digoxin.

Authors:  G H Burnett; R L Conklin; G W Wasson; A A MacKinney
Journal:  Clin Chem       Date:  1973-07       Impact factor: 8.327

4.  Influence of serum digoxin concentration measurements on frequency of digitoxicity.

Authors:  J Koch-Weser; D W Duhme; D J Greenblatt
Journal:  Clin Pharmacol Ther       Date:  1974-07       Impact factor: 6.875

5.  The radioimmunoassay of plasma-digoxin.

Authors:  J J Zeegers; A H Maas; A F Willebrands; H H Kruyswijk; G Jambroes
Journal:  Clin Chim Acta       Date:  1973-02-28       Impact factor: 3.786

6.  [Determination of serum-digoxin concentrations by radioimmunoassay].

Authors:  D Larbig; K Kochsiek
Journal:  Klin Wochenschr       Date:  1971-09-15

7.  [Radioimmunochemical assay of digoxin and digoxin derivatives].

Authors:  D Larbig; K Kochsiek
Journal:  Dtsch Med Wochenschr       Date:  1972-09-01       Impact factor: 0.628

8.  A solid phase radioimmunoassay for digoxin and its acylated derivatives.

Authors:  D Arndts
Journal:  Naunyn Schmiedebergs Arch Pharmacol       Date:  1975       Impact factor: 3.000

9.  Comparison of five radioimmunoassays and enzyme bioassay for measurement of digoxin in blood.

Authors:  A A MacKinney; G H Burnett; R L Conklin; G W Wasson
Journal:  Clin Chem       Date:  1975-06       Impact factor: 8.327

10.  A review of radioimmunoassay for steroids.

Authors:  E Nieschlag; E J Wickings
Journal:  Z Klin Chem Klin Biochem       Date:  1975-07
View more
  1 in total

1.  Drug interactions with digoxin.

Authors:  D D Brown; R Spector; R P Juhl
Journal:  Drugs       Date:  1980-09       Impact factor: 9.546

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.