Literature DB >> 6510421

Comparison of measurement of effective renal plasma flow by single plasma sample and plasma disappearance slope/volume methods.

W N Tauxe, E V Dubovsky, T E Kidd.   

Abstract

Numerous simplified methods for the estimation of ERPF have described, including the so-called slope/intercept (SI) methods, based on the analysis of the slope of certain segments of the 131I-OIH plasma disappearance curve and its y-axis intercept, and the single sample (SS) clearance method, based on theoretical volumes of OIH distribution at some fixed time after injection. Using ERPFs estimated from compartment analysis of the entire 60-min plasma disappearance curve, we have compared the errors of data calculated from use of eight SI methods made at various times along the disappearance curve with that from the optimum SS curve. The errors obtained from the SS method were approximately 50% less than those obtained from the SI methods. The errors of the SI methods are greater at both ends of the 60-min plasma curve than when samples are drawn near the mid-time. The SS method appears to be the method of choice for the estimation of ERPF using single injection techniques.

Mesh:

Substances:

Year:  1984        PMID: 6510421     DOI: 10.1007/bf00563166

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  12 in total

1.  MEASUREMENT OF EFFECTIVE RENAL PLASMA FLOW WITH SODIUM IODOHIPPURATE I-131.

Authors:  R D WAGONER; W N TAUXE; F T MAHER; J C HUNT
Journal:  JAMA       Date:  1964-03-14       Impact factor: 56.272

2.  The theory of tracer experiments with 131I-labelled plasma proteins.

Authors:  C M MATTHEWS
Journal:  Phys Med Biol       Date:  1957-07       Impact factor: 3.609

3.  Effective renal plasma flow: estimation from theoretical volumes of distribution of intravenously injected 131-I orthoiodohippurate.

Authors:  W N Tauxe; F T Maher; W F Taylor
Journal:  Mayo Clin Proc       Date:  1971-08       Impact factor: 7.616

4.  Simplified clearance techniques. The single injection method and its modifications.

Authors:  B Truniger; A Donath; M Kappeler
Journal:  Helv Med Acta       Date:  1968-03

5.  A single injection method for measurement of effective renal plasma flow.

Authors:  M D Ram; K Evans; G D Chisholm
Journal:  Br J Urol       Date:  1968-08

6.  Correlation of renal blood flow determined by the single injection of Hippuran-I 131 with direct measurements of flow.

Authors:  W H Pritchard; R W Eckstein; W J MacIntyre; E Dabaj
Journal:  Am Heart J       Date:  1965-12       Impact factor: 4.749

7.  [The slope clearance method in renal functional diagnosis. J-131-hippurate clearance is used as an example].

Authors:  M Böttcher; J Neumann; G Esther; P W Wüstenberg
Journal:  Z Gesamte Inn Med       Date:  1979-10-01

8.  [Measurement of radiohippuran clearance after a single injection, using external detection, a 1-compartment model and a blood sample taken after 15 min. Evaluation of the method].

Authors:  A Chapman; C Dellieux; J Rohan; J Guedon
Journal:  J Urol Nephrol (Paris)       Date:  1971-12

9.  Simplified hippuran clearance. Measurement of renal function in man with simplified hippuran clearances.

Authors:  M D Blaufox; J P Merrill
Journal:  Nephron       Date:  1966       Impact factor: 2.847

10.  New formulas for the calculation of effective renal plasma flow.

Authors:  W N Tauxe; E V Dubovsky; T Kidd; F Diaz; L R Smith
Journal:  Eur J Nucl Med       Date:  1982
View more
  2 in total

1.  Comparison of the effects of dopamine, dobutamine, and dopexamine upon renal blood flow: a study in normal healthy volunteers.

Authors:  S Mousdale; P A Clyburn; A M Mackie; N D Groves; M Rosen
Journal:  Br J Clin Pharmacol       Date:  1988-05       Impact factor: 4.335

2.  Comparison of measurement of glomerular filtration rate by single sample, plasma disappearance slope/intercept and other methods.

Authors:  P G Tepe; W N Tauxe; A Bagchi; P Rezende; P R Krishnaiah
Journal:  Eur J Nucl Med       Date:  1987
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.