Literature DB >> 6507962

Impedance plethysmography in the diagnosis of arterial and venous disease.

F A Anderson.   

Abstract

The objective of this paper is to review the theoretical basis and clinical application of electrical impedance plethysmography in the noninvasive evaluation of peripheral arterial and venous disease. Theoretical, experimental and clinical studies have now demonstrated a direct relationship between electrical impedance changes and limb volume changes. Potential sources of error have also been identified. This has led to the development of clinical tests based on impedance plethysmography for the detection of peripheral arterial disease, venous insufficiency and venous outflow obstruction. Impedance plethysmography, using the method of venous occlusion, is presently the most commonly employed noninvasive method for the detection of deep venous thrombosis.

Entities:  

Mesh:

Year:  1984        PMID: 6507962     DOI: 10.1007/bf02410293

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  15 in total

1.  Electrical impedance plethysmography; a physical and physiologic approach to peripheral vascular study.

Authors:  J NYBOER
Journal:  Circulation       Date:  1950-12       Impact factor: 29.690

2.  Influence of erythrocyte veloicty on impedance plethysmographic measurements.

Authors:  R A Peura; B C Penney; J Arcuri; F A Anderson; H B Wheeler
Journal:  Med Biol Eng Comput       Date:  1978-03       Impact factor: 2.602

3.  The impedance plethysmographic sampling field in the human calf.

Authors:  B C Penney; L M Narducci; R A Peura; F A Anderson; H B Wheeler
Journal:  IEEE Trans Biomed Eng       Date:  1979-04       Impact factor: 4.538

4.  An application of electrocardiographic lead theory to impedance plethysmography.

Authors:  D B Geselowitz
Journal:  IEEE Trans Biomed Eng       Date:  1971-01       Impact factor: 4.538

5.  Evaluation of the parallel conductor theory for measuring human limb blood flow by electrical admittance plethysmography.

Authors:  H Shimazu; K Yamakoshi; T Togawa; M Fukuoka; H Ito
Journal:  IEEE Trans Biomed Eng       Date:  1982-01       Impact factor: 4.538

6.  Noninvasive measurement of hematocrit by electrical admittance plethysmography technique.

Authors:  K I Yamakoshi; H Shimazu; T Togawa; M Fukuoka; H Ito
Journal:  IEEE Trans Biomed Eng       Date:  1980-03       Impact factor: 4.538

7.  Admittance plethysmography for accurate measurement of human limb blood flow.

Authors:  K I Yamakoshi; H Shimazu; T Togawa; H Ito
Journal:  Am J Physiol       Date:  1978-12

8.  Impedance plethysmography: the origin of electrical impedance changes measured in the human calf.

Authors:  F A Anderson; B C Penney; N A Patwardhan; H B Wheeler
Journal:  Med Biol Eng Comput       Date:  1980-03       Impact factor: 2.602

9.  The specific resistance of biological material--a compendium of data for the biomedical engineer and physiologist.

Authors:  L A Geddes; L E Baker
Journal:  Med Biol Eng       Date:  1967-05

10.  Noninvasive detection of axillary and subclavian venous thrombosis by impedance plethysmography.

Authors:  N A Patwardhan; F A Anderson; B S Cutler; H B Wheeler
Journal:  J Cardiovasc Surg (Torino)       Date:  1983 May-Jun       Impact factor: 1.888

View more
  3 in total

1.  Automated venous occlusion plethysmograph.

Authors:  A M Sinton; A D Seagar; F M Davis
Journal:  Med Biol Eng Comput       Date:  1988-05       Impact factor: 2.602

2.  Multi-Channel Bioimpedance System for Detecting Vascular Tone in Human Limbs: An Approach.

Authors:  Ahmad Hammoud; Alexey Tikhomirov; Galina Myasishcheva; Zein Shaheen; Alexander Volkov; Andrey Briko; Sergey Shchukin
Journal:  Sensors (Basel)       Date:  2021-12-26       Impact factor: 3.576

Review 3.  Peripheral vascular disease assessment in the lower limb: a review of current and emerging non-invasive diagnostic methods.

Authors:  Elham Shabani Varaki; Gaetano D Gargiulo; Stefania Penkala; Paul P Breen
Journal:  Biomed Eng Online       Date:  2018-05-11       Impact factor: 2.819

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.