Literature DB >> 6506326

25 + 1 channel pulsed ultrasound Doppler velocity meter for quantitative flow measurements and turbulence analysis.

M Casty, D P Giddens.   

Abstract

A multichannel pulsed ultrasound Doppler instrument designed to measure velocity and volume flow rate quantitatively has been applied for turbulence detection. A 7-MHz transmitting frequency and a phase locked loop technique for the frequency to velocity conversion have been used to obtain high temporal resolution in the single channel mode. To provide for reliable positioning of the single gate within the arterial lumen the device could first be operated in the multichannel mode measuring the velocity profiles with zero crossing detection methods. Measurements of the velocity in the center of the lumen of the common and internal carotid arteries have been recorded on a beat to beat basis. An ensemble average of 16 consecutive pulses was determined. Thereafter, the root mean square of the differences between ensemble average and individual velocity pulses was computed, and a disturbance index was defined by dividing the disturbance velocity by the mean velocity. First clinical results show that the method presented is a valuable complement to the analysis of flow pulse patterns in the transcutaneous examination of carotid arteries.

Mesh:

Year:  1984        PMID: 6506326     DOI: 10.1016/0301-5629(84)90215-1

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  5 in total

1.  Effect of compliance mismatch on flow disturbances in a model of an arterial graft replacement.

Authors:  F Miyawaki; T V How; D Annis
Journal:  Med Biol Eng Comput       Date:  1990-09       Impact factor: 2.602

Review 2.  [Perioperative echocardiography: basic principles].

Authors:  M Nowak; P Rosenberger; T W Felbinger; A E Götz; S K Shernan; K Unertl; H K Eltzschig
Journal:  Anaesthesist       Date:  2006-03       Impact factor: 1.041

3.  Evaluation of distal turbulence intensity for the detection of both plaque ulceration and stenosis grade in the carotid bifurcation using clinical Doppler ultrasound.

Authors:  Emily Y Wong; Hristo N Nikolov; Richard N Rankin; David W Holdsworth; Tamie L Poepping
Journal:  Eur Radiol       Date:  2012-12-18       Impact factor: 5.315

4.  Detection of low-grade arterial stenosis using an automatic minimum-flow-velocity tracking system (MVTS) as an adjunct to pulsed ultrasonic Doppler vessel imaging.

Authors:  S J Calil; V C Roberts
Journal:  Med Biol Eng Comput       Date:  1985-07       Impact factor: 2.602

5.  Computer assisted Doppler waveform analysis and ultrasound derived turbulence intensity ratios can predict early hyperplasia development in newly created vascular access fistula: Pilot study, methodology and analysis.

Authors:  Matthew Bartlett; Vanessa Diaz-Zuccarini; Janice Tsui
Journal:  JRSM Cardiovasc Dis       Date:  2021-03-20
  5 in total